Literature DB >> 11144978

Fluid mechanic assessment of the total cavopulmonary connection using magnetic resonance phase velocity mapping and digital particle image velocimetry.

A E Ensley1, A Ramuzat, T M Healy, G P Chatzimavroudis, C Lucas, S Sharma, R Pettigrew, A P Yoganathan.   

Abstract

The total cavopulmonary connection (TCPC) is currently the most promising modification of the Fontan surgical repair for single ventricle congenital heart disease. The TCPC involves a surgical connection of the superior and inferior vena cavae directly to the left and right pulmonary arteries, bypassing the right heart. In the univentricular system, the ventricle experiences a workload which may be reduced by optimizing the cavae-to-pulmonary anastomosis. The hypothesis of this study was that the energetic efficiency of the connection is a consequence of the fluid dynamics which develop as a function of connection geometry. Magnetic resonance phase velocity mapping (MRPVM) and digital particle image velocimetry (DPIV) were used to evaluate the flow patterns in vitro in three prototype glass models of the TCPC: flared zero offset, flared 14 mm offset, and straight 21 mm offset. The flow field velocity along the symmetry plane of each model was chosen to elucidate the fluid mechanics of the connection as a function of the connection geometry and pulmonary artery flow split. The steady flow experiments were conducted at a physiologic cardiac output (4 L/min) over three left/right pulmonary flow splits (70/30, 50/50, and 30/70) while keeping the superior/inferior vena cavae flow ratio constant at 40/60. MRPVM, a noninvasive clinical technique for measuring flow field velocities, was compared to DPIV, an established in vitro fluid mechanic technique. A comparison between the results from both techniques showed agreement of large scale flow features, despite some discrepancies in the detailed flow fields. The absence of caval offset in the flared zero offset model resulted in significant caval flow collision at the connection site. In contrast, offsetting the cavae reduced the flow interaction and caused a vortex-like low velocity region between the caval inlets as well as flow disturbance in the pulmonary artery with the least total flow. A positive correlation was also found between the direct caval flow collision and increased power losses. MRPVM was able to elucidate these important fluid flow features, which may be important in future modifications in TCPC surgical designs. Using MRPVM, two- and three-directional velocity fields in the TCPC could be quantified. Because of this, MRPVM has the potential to provide accurate velocity information clinically and, thus, to become the in vivo tool for TCPC patient physiological/functional assessment.

Entities:  

Mesh:

Year:  2000        PMID: 11144978     DOI: 10.1114/1.1317533

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  6 in total

1.  A dual contrast injection technique for multidetector computed tomography angiography of Fontan procedures.

Authors:  S B Greenberg; Sadaf T Bhutta
Journal:  Int J Cardiovasc Imaging       Date:  2007-09-06       Impact factor: 2.357

2.  Magnetic resonance flow analysis of classic and extracardiac Fontan procedures: the seesaw sign.

Authors:  S Bruce Greenberg; W Robert Morrow; Michiaki Imamura; Jonathan Drummond-Webb
Journal:  Int J Cardiovasc Imaging       Date:  2004-10       Impact factor: 2.357

3.  Hemodynamic performance of stage-2 univentricular reconstruction: Glenn vs. hemi-Fontan templates.

Authors:  Kerem Pekkan; Lakshimi P Dasi; Diane de Zélicourt; Kartik S Sundareswaran; Mark A Fogel; Kirk R Kanter; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2008-11-06       Impact factor: 3.934

Review 4.  Modeling the Fontan circulation: where we are and where we need to go.

Authors:  C G DeGroff
Journal:  Pediatr Cardiol       Date:  2007-10-05       Impact factor: 1.655

5.  The total cavopulmonary connection resistance: a significant impact on single ventricle hemodynamics at rest and exercise.

Authors:  Kartik S Sundareswaran; Kerem Pekkan; Lakshmi P Dasi; Kevin Whitehead; Shiva Sharma; Kirk R Kanter; Mark A Fogel; Ajit P Yoganathan
Journal:  Am J Physiol Heart Circ Physiol       Date:  2008-10-17       Impact factor: 4.733

6.  Cardiovascular magnetic resonance evaluation of aortic stenosis severity using single plane measurement of effective orifice area.

Authors:  Julio Garcia; Oscar R Marrufo; Alfredo O Rodriguez; Eric Larose; Philippe Pibarot; Lyes Kadem
Journal:  J Cardiovasc Magn Reson       Date:  2012-04-06       Impact factor: 5.364

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.