The effects of UV-irradiation on the ESR-dosimetry of tooth enamel.

J Nilsson1, E Lund, A Lund.   

Abstract

Tooth enamel has been shown to be an excellent dosimeter material for retrospective dosimetry. A complication is that it is sensitive to ultraviolet light (UV), creating a signal that interferes with the dosimetric signal. Irradiation of tooth enamel by UV-light induces a mixture of stable and unstable free radicals. The unstable radicals disappear in about three weeks. Stable radicals are created both at the dosimetric peak and at the same g-value as the native peak. The stable peak coinciding with the native peak shows saturation behavior both for UVA/B- and UVC-light. The signal intensity from the sun is roughly estimated to induce a signal comparable to 15 mGy/h from 60 kV X-rays. The blue lamps used by dentists when hardening plastic repairs contain a narrow tail in the UVA/B-region, and it is shown here that these lamps also contribute to the stable peak coincident with the native peak. The contribution to the dosimetry peak, though negligible, at least for the irradiation times is used in this work. Most of the problems with UVA/B-induced signal contributions can probably be avoided by not using front teeth and teeth close to plastic repairs.

Entities:  

Mesh:

Year:  2001        PMID: 11144243     DOI: 10.1016/s0969-8043(99)00275-4

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  3 in total

1.  Determination of the Average Native Background and the Light-Induced EPR Signals and their Variation in the Teeth Enamel Based on Large-Scale Survey of the Population.

Authors:  Alexander I Ivannikov; Artem M Khailov; Sergey P Orlenko; Valeri G Skvortsov; Valeri F Stepanenko; Kassym Sh Zhumadilov; Benjamin B Williams; Ann B Flood; Harold M Swartz
Journal:  Radiat Prot Dosimetry       Date:  2016-07-13       Impact factor: 0.972

2.  Physically-based biodosimetry using in vivo EPR of teeth in patients undergoing total body irradiation.

Authors:  Benjamin B Williams; Ruhong Dong; Roberto J Nicolalde; Thomas P Matthews; David J Gladstone; Eugene Demidenko; Bassem I Zaki; Ildar K Salikhov; Piotr N Lesniewski; Harold M Swartz
Journal:  Int J Radiat Biol       Date:  2011-06-23       Impact factor: 2.694

3.  UV effects in tooth enamel and their possible application in EPR dosimetry with front teeth.

Authors:  S Sholom; M Desrosiers; V Chumak; N Luckyanov; S L Simon; A Bouville
Journal:  Health Phys       Date:  2010-02       Impact factor: 1.316

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.