Radioassays and experimental evaluation of dose calibrator settings for 18F.

B E Zimmerman1, G J Kubicek, J T Cessna, P S Plascjak, W C Eckelman.   

Abstract

The positron emitter 18F continues to be one of the most important imaging radionuclides in diagnostic nuclear medicine. Assays of radiopharmaceuticals containing this nuclide are often performed in the clinic using commercial reentrant ionization chambers, or "dose calibrators". Meaningful quantitative clinical studies require accurate knowledge of the injected activity which requires proper calibration of these instruments. Radioassays were performed at the National Institute of Standards and Technology (NIST) on a solution of 18F produced at the National Institutes of Health (NIH) using 4pibeta liquid scintillation (fS) counting with 3H-standard efficiency tracing. Cocktails containing water fractions of approximately 0.9 and 9% (both as saline) were used. The massic activity values were measured to be 2.52+/-0.06 and 2.50+/-0.03 MBq g(-1), respectively, for the 0.9 and 9% water cocktails as of the reference time. The uncertainties on the activity measurements are expanded (k = 2) uncertainties. The largest uncertainty component was found to be the repeatability on a single LS source, with the cocktails containing 0.9% water fraction exhibiting a larger variability by nearly a factor of two. Reproducibility between LS cocktails with the same water fraction was also found to be a large uncertainty component, but with a value less than half that due to measurement repeatability. Radionuclidic impurities consisted of 48V and 46Sc, at levels of 0.11+/-0.08% (expanded uncertainties) and approximately 2 x 10(-3)% (upper limit) relative to the activity of the 18F, as of the reference time. Dose calibrator dial settings for measuring solutions of 18F were experimentally determined for Capintec CRC-12 and CRC-35R dose calibrators in three measurement geometries: a 5-ml standard NIST ampoule (two ampoules measured), a 12-ml plastic syringe containing 9 ml of solution and a 10-ml Mallinckrodt molded dose vial filled with 5 ml of solution. The experimental dial settings (and the corresponding expanded uncertainties) for these geometries were found to be 477+/-7, 474+/-6, 482+/-6 and 463+/-7 for the two ampoules, the syringe and the dose vial, respectively, in the CRC-12. The dial settings determined for the CRC-35R were 472+/-7, 470+/-7, 464+/-6 and 456+/-6 for the two ampoules, the syringe, and the dose vial, respectively. The uncertainties in the dial settings are expanded uncertainties. Comparisons between the empirically determined dial settings and the manufacturer's recommended setting of "439" indicate that use of the manufacturer's setting overestimates the activity by between 3 and 6%, depending upon the geometry used.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11144241     DOI: 10.1016/s0969-8043(99)00260-2

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  8 in total

1.  Radionuclide calibrator responses for 224Ra in solution and adsorbed on calcium carbonate microparticles.

Authors:  Elisa Napoli; Jeffrey T Cessna; Leticia Pibida; Ryan Fitzgerald; Gro E Hjellum; Denis E Bergeron
Journal:  Appl Radiat Isot       Date:  2020-06-12       Impact factor: 1.513

2.  Tandem Mass Spectrometry as an Independent Method for Corroborating Fluorine-18 Radioactivity Measurements in Positron Emission Tomography.

Authors:  H Umesha Shetty; Cheryl L Morse; Victor W Pike
Journal:  ACS Meas Sci Au       Date:  2022-06-23

3.  Characterization of fast-decaying PET radiotracers solely through LC-MS/MS of constituent radioactive and carrier isotopologues.

Authors:  H Umesha Shetty; Cheryl L Morse; Yi Zhang; Victor W Pike
Journal:  EJNMMI Res       Date:  2013-01-12       Impact factor: 3.138

4.  Comparison of methods to determine accurate dose calibrator activity measurements.

Authors:  Lidia Strigari; Marcello Benassi; Pierino De Felice; Marco D'Andrea; Aldo Fazio; Sandro Nocentini; Annelisa d'Angelo; Alessia Ceccatelli
Journal:  J Exp Clin Cancer Res       Date:  2008-07-01

5.  A Review of NIST Primary Activity Standards for (18)F: 1982 to 2013.

Authors:  Denis E Bergeron; Jeffrey T Cessna; Bert M Coursey; Ryan Fitzgerald; Brian E Zimmerman
Journal:  J Res Natl Inst Stand Technol       Date:  2014-08-27

6.  Standardization of (68)Ge/(68)Ga Using Three Liquid Scintillation Counting Based Methods.

Authors:  B E Zimmerman; J T Cessna; R Fitzgerald
Journal:  J Res Natl Inst Stand Technol       Date:  2008-10-01

7.  ARAS: an automated radioactivity aliquoting system for dispensing solutions containing positron-emitting radioisotopes.

Authors:  Alex A Dooraghi; Lewis Carroll; Jeffrey Collins; R Michael van Dam; Arion F Chatziioannou
Journal:  EJNMMI Res       Date:  2016-03-09       Impact factor: 3.138

8.  Development of a non-radiometric method for measuring the arterial input function of a 11C-labeled PET radiotracer.

Authors:  H Umesha Shetty; Sami S Zoghbi; Cheryl L Morse; Aneta Kowalski; Jussi Hirvonen; Robert B Innis; Victor W Pike
Journal:  Sci Rep       Date:  2020-10-15       Impact factor: 4.996

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.