Literature DB >> 11139970

Reflex autonomic modulation of automatically measured repolarization parameters.

A Ghuran1, V Batchvarov, P Dilaveris, P Färbom, A J Camm, M Malik.   

Abstract

Automatic recognition of repolarization abnormalities from the standard electrocardiogram (ECG) is of considerable clinical importance. This study examined the autonomic variations in automatically measured repolarization parameters, including maximum QT interval (QTmax), global QT dispersion (QTd), T area dispersion (T area D) and principal component analysis ratio 2 (PCA-2). Twelve-lead ECGs were recorded continuously in 40 healthy subjects during supine, sitting and standing positions, and during the Valsalva maneuver. With the exception of PCA-2, the other repolarization parameters correlated either moderately or strongly during the steady-state supine position. QTmax, PCA-2, and T area D decreased significantly between supine and sitting position (P < 0.001, P < 0.001 and P < 0.01, respectively). QTmax, QTD, and T area D decreased significantly between sitting and standing (P < 0.001, P < 0.05 and P < 0.01, respectively). All parameters significantly decreased between supine and standing position: QTmax (P < 0.001), QTD (P < 0.05), PCA-2 (P < 0.05) and T area D (P < 0.001). During Valsalva, only PCA-2 increased significantly (P < 0.001) between supine and standing position. There were no significant changes in QT dispersion and dispersion of T wave area during Valsalva, compared to baseline, in both supine and standing positions. Automatic conventional measures of repolarization heterogeneity have limited practical value in detecting the effects of autonomic changes on ventricular repolarization. Newer concepts evaluating spatial and temporal irregularity of ventricular repolarization are still needed to reliably detect the effects of autonomic activity on ventricular repolarization.

Entities:  

Mesh:

Year:  2000        PMID: 11139970     DOI: 10.1111/j.1540-8159.2000.tb07065.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

1.  T-wave morphology parameters based on principal component analysis reproducibility and dependence on T-offset position.

Authors:  Fabrice Extramiana; Abdeddayem Haggui; Pierre Maison-Blanche; Rémi Dubois; Seiji Takatsuki; Philippe Beaufils; Antoine Leenhardt
Journal:  Ann Noninvasive Electrocardiol       Date:  2007-10       Impact factor: 1.468

2.  Body Surface Mapping of Ventricular Repolarization Heterogeneity: An Ex-vivo Multiparameter Study.

Authors:  Marianna Meo; Pietro Bonizzi; Laura R Bear; Matthijs Cluitmans; Emma Abell; Michel Haïssaguerre; Olivier Bernus; Rémi Dubois
Journal:  Front Physiol       Date:  2020-08-13       Impact factor: 4.566

3.  Valsalva Maneuver and Strain-Related ECG Changes.

Authors:  Seyed Mehran Hosseini; Mohsen Jamshir
Journal:  Res Cardiovasc Med       Date:  2015-09-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.