Automatic optimization of resting and exercise atrioventricular interval using a peak endocardial acceleration sensor: validation with Doppler echocardiography and direct cardiac output measurements.

S K Leung1, C P Lau, C T Lam, S Ho, H F Tse, C M Yu, K Lee, M O Tang, K M To, F Renesto.   

Abstract

Peak endocardial acceleration (PEA) measured by an implantable acceleration sensor inside the tip of a pacing lead reflects ventricular filling and myocardial contractility. The contribution of the plateau phase of PEA as an indicator of optimal ventricular filling, hence of the appropriate atrioventricular interval (AVI) at rest and during exercise, was studied in 12 patients (age 69 +/- 6 years) with complete AV block and a PEA sensing DDDR pacemakers (Living 1 Plus, Sorin Biomedica). At a mean resting heart rate of 79 +/- 15 beats/min, the mean AVI optimized by PEA versus Doppler echocardiography (echo) were identical (142 +/- 37 vs 146 +/- 26 ms, P = 0.59). During submaximal exercise at a mean heart rate of 134 +/- 6 beats/min, AVI optimized by PEA was 135 +/- 37 ms. Cardiac output at rest, measured by the CO2 rebreathing method, was comparable with AVI determined by echo versus PEA (4.3 +/- 2.9 and 3.7 +/- 2.4 L/min, respectively), and increased to the same extent (8.0 +/- 3.9 vs 8.3 +/- 5.2 L/min) during submaximal exercise. In patients with AV block, AVI automatically set by PEA was comparable with AVI manually optimized by Doppler echocardiography and was associated with comparable exercise induced hemodynamic changes.

Entities:  

Mesh:

Year:  2000        PMID: 11139919     DOI: 10.1111/j.1540-8159.2000.tb07014.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  6 in total

Review 1.  Advances in devices for cardiac resynchronization in heart failure.

Authors:  Chu-Pak Lau; Serge Barold; Hung-Fat Tse; Kathy Lai-Fun Lee; Hon-Wah Chan; Katherine Fan; Elaine Chau; Cheuk-Man Yu
Journal:  J Interv Card Electrophysiol       Date:  2003-10       Impact factor: 1.900

2.  [New technologies in the optimization of CRT programming].

Authors:  A Kloppe; B Lemke; M Zarse
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2008-03

Review 3.  Atrioventricular and interventricular delay optimization in cardiac resynchronization therapy: physiological principles and overview of available methods.

Authors:  Patrick Houthuizen; Frank A L E Bracke; Berry M van Gelder
Journal:  Heart Fail Rev       Date:  2011-05       Impact factor: 4.214

4.  First clinical evaluation of an atrial haemodynamic sensor lead for automatic optimization of cardiac resynchronization therapy.

Authors:  David Duncker; Peter Paul Delnoy; Herbert Nägele; Jacques Mansourati; Lluís Mont; Frédéric Anselme; Petra Stengel; Francesca Anselmi; Hanno Oswald; Christophe Leclercq
Journal:  Europace       Date:  2015-05-14       Impact factor: 5.214

5.  A relative value method for measuring and evaluating cardiac reserve.

Authors:  Shouzhong Xiao; Xingming Guo; Xiaobo Sun; Zifu Xiao
Journal:  Biomed Eng Online       Date:  2002-12-06       Impact factor: 2.819

6.  Heart failure monitoring with a cardiac resynchronization therapy device-based cardiac contractility sensor: a case series.

Authors:  Jacques Mansourati; Mélanie Heurteau; Jérôme Abaléa
Journal:  J Med Case Rep       Date:  2014-01-27
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.