Aneurysm sac pressure measurements after endovascular repair of abdominal aortic aneurysms.

R A Baum1, J P Carpenter, C Cope, M A Golden, O C Velazquez, D G Neschis, M E Mitchell, C F Barker, R M Fairman.   

Abstract

OBJECTIVES: The goal of endovascular grafting of abdominal aortic aneurysms (AAAs) is to exclude the aneurysm sac from systemic pressure and thereby decrease the risk of rupture. Unlike conventional open surgery, branch vessels in the sac (eg, lumbar artery and inferior mesenteric artery [IMA]) are not ligated and can potentially transmit pressure. The purpose of our investigation was to evaluate the feasibility of various interventional techniques for measuring pressure within the aneurysm sac in patients who had undergone endovascular repair of AAAs.
METHODS: Sac pressure measurements were performed in 21 patients who had undergone stent graft repair of AAAs. Seventeen of 21 patients had endoleaks demonstrated on 30-day computed tomographic (CT) scans. Access to the aneurysm sac in these patients was through direct translumbar sac puncture (5 patients), through a patent IMA accessed via the superior mesenteric artery (SMA) (9 patients), or by direct cannulation around attachment sites (3 patients). Four patients had perioperative pressure measurements obtained through catheters positioned along side of the endovascular graft at the time of its deployment. Two of these catheters were left in position for 30 hours during which time CT and conventional angiography were performed. Pressures were determined with standard arterial-line pressure transduction techniques and compared with systemic pressure in each patient.
RESULTS: Elevated sac pressure was found in all patients. The sac pressure in patients with endoleaks was found to be systemic (15 patients) or near systemic (2 patients) and all had pulsatile waveforms. Elevated sac pressures were also found in patients without CT or angiographic evidence of endoleak (2 patients). Injection of the sacs in two of these patients revealed a patent lumbar artery and an IMA.
CONCLUSIONS: It is possible to measure pressures from within the aneurysm sac in patients with stent grafts with a variety of techniques. Patients may continue to have pressurized AAA sacs despite endovascular AAA repair. Endoleaks transmit pulsatile pressure into the aneurysm sac regardless of the type. It is possible to have systemic sac pressures without evidence of endoleaks on CT or angiography.

Entities:  

Mesh:

Year:  2001        PMID: 11137921     DOI: 10.1067/mva.2001.111807

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  15 in total

1.  Increasing incidence of midterm and long-term complications after endovascular graft repair of abdominal aortic aneurysms: a note of caution based on a 9-year experience.

Authors:  T Ohki; F J Veith; P Shaw; E Lipsitz; W D Suggs; R A Wain; M Bade; M Mehta; N Cayne; J Cynamon; J Valldares; J McKay
Journal:  Ann Surg       Date:  2001-09       Impact factor: 12.969

2.  Iatrogenic Ureteral Injury during Translumbar Embolization of a Type II Endoleak.

Authors:  Charles T Burke
Journal:  Semin Intervent Radiol       Date:  2007-09       Impact factor: 1.513

3.  Type IA endoleak embolization after TEVAR via direct transthoracic puncture.

Authors:  Yoshiaki Katada; Shunichi Kondo; Eitoshi Tsuboi; Ken Nakamura; Kyu Rokkaku; Yoshihito Irie
Journal:  Jpn J Radiol       Date:  2015-01-28       Impact factor: 2.374

4.  Significance of initial aortic aneurysm pressure sensor readings varies with aortic endograft design.

Authors:  Gautam Shrikhande; Sikandar Khan; Hafiz Hussain; Alicia Menezes; James McKinsey; Harry Bush
Journal:  World J Surg       Date:  2010-12       Impact factor: 3.352

Review 5.  Management of Endoleaks.

Authors:  James Chen; S William Stavropoulos
Journal:  Semin Intervent Radiol       Date:  2015-09       Impact factor: 1.513

6.  Aortic aneurysm sac pressure measurements after endovascular repair using an implantable remote sensor: initial experience and short-term follow-up.

Authors:  Hanno Hoppe; Jocelyn A Segall; Timothy K Liem; Gregory J Landry; John A Kaufman
Journal:  Eur Radiol       Date:  2007-12-20       Impact factor: 5.315

7.  Endoleak following endovascular abdominal aortic aneurysm repair: implications for duration of screening.

Authors:  Matthew A Corriere; Irene D Feurer; Stacey Y Becker; Jeffery B Dattilo; Marc A Passman; Raul J Guzman; Thomas C Naslund
Journal:  Ann Surg       Date:  2004-06       Impact factor: 12.969

8.  Abdominal aortic aneurysm: Treatment options, image visualizations and follow-up procedures.

Authors:  Zhong-Hua Sun
Journal:  J Geriatr Cardiol       Date:  2012-03       Impact factor: 3.327

9.  Detecting endoleaks after endovascular AAA repair with a minimally invasive, implantable, telemetric pressure sensor: an in vitro study.

Authors:  Fabian Springer; Roland Schlierf; Joachim-Georg Pfeffer; Andreas H Mahnken; Uwe Schnakenberg; Thomas Schmitz-Rode
Journal:  Eur Radiol       Date:  2007-03-06       Impact factor: 7.034

10.  Correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter during endovascular repair of abdominal aortic aneurysm.

Authors:  Pierre Galvagni Silveira; Christopher William Teixeira Miller; Rafael Freygang Mendes; Gilberto Nascimento Galego
Journal:  Clinics (Sao Paulo)       Date:  2008-02       Impact factor: 2.365

View more