Literature DB >> 11137920

Identification of factors predictive of lower extremity vein graft thrombosis.

K D Gibson1, M T Caps, D Gillen, R O Bergelin, J Primozich, D E Strandness.   

Abstract

OBJECTIVE: The objective of this study was to assess the prognostic value of hemodynamic parameters measured with duplex ultrasound scan, together with other important graft and patient characteristics, in predicting lower extremity vein graft thrombosis.
METHODS: A total of 165 lower extremity vein grafts were entered prospectively into a postoperative duplex ultrasound scan surveillance program with examinations performed at 1, 2, 3, 4, 6, 9, 12, 18, and 24 months, and annually thereafter. Duplex scan-derived blood flow velocity measurements were recorded at 1562 patient visits over 7 years. Graft patency was determined after each visit, and an analysis of factors predictive of vein graft thrombosis was performed with Poisson regression.
RESULTS: Thirty-two episodes of first-time graft thrombosis occurred, 23 of which were permanent. One-, 3-, and 5-year secondary graft patency rates were 90%, 86%, and 79%, respectively. In multivariate analyses, duplex scan velocity measurements predictive of lower extremity graft thrombosis included the maximum velocity ratio (Vr) in association with a graft stenosis and the mean graft peak systolic velocity (MGV) within nonstenotic portions of the body of the graft. The incidence of graft thrombosis among grafts without inflow/outflow stenoses, with Vr less than 3.5, and with MGV 50 cm/s or more, was 2.9% per year. Incidence rates were considerably higher among grafts with a of Vr of 3.5 or more (incidence rate ratio = 7.0; 95% CI, 3.4-14.6) or an MGV less than 50 cm/s (incidence rate ratio = 6.5; 95% CI, 3.3-13.1). In grafts without identifiable inflow, outflow, or graft stenoses, there was no association between MGV and the risk of graft thrombosis.
CONCLUSION: Duplex scan velocity measurements are valid predictors of impending graft thrombosis. A Vr of 3.5 or more and an MGV less than 50 cm/s are the best predictive measures. Repair of correctable graft lesions with a Vr of 3.5 or more, or inflow, outflow, or graft lesions associated with an MGV less than 50 cm/s are recommended. Grafts without detectable inflow, outflow, or graft stenoses, regardless of MGV, may be safely followed.

Entities:  

Mesh:

Year:  2001        PMID: 11137920     DOI: 10.1067/mva.2001.112214

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  1 in total

1.  Prediction of graft patency and mortality after distal revascularization and interval ligation for hemodialysis access-related hand ischemia.

Authors:  Salvatore T Scali; Catherine K Chang; Dan Raghinaru; Michael J Daniels; Adam W Beck; Robert J Feezor; Scott A Berceli; Thomas S Huber
Journal:  J Vasc Surg       Date:  2012-12-12       Impact factor: 4.268

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.