Literature DB >> 11137793

MRI guided segmentation and quantification of SPECT images of the basal ganglia: a phantom study.

M Koole1, K V Laere, R V de Walle , S Vandenberghe, L Bouwens, I Lemahieu, R A Dierckx.   

Abstract

Due to the limited resolution of single-photon emission computed tomography (SPECT) imaging devices, tissue interfaces are not well defined in the reconstructed image, even though resolution recovery techniques may be used during reconstruction. Therefore, segmentation of a particular region and quantification of the tracer uptake in that region is critical due to spillover effects, when based on the SPECT image only. In this study, we present two methods for quantification of tracer uptake in a SPECT image, defined by a matched high resolution structural magnetic resonance image. We show preliminary results of both techniques, when applied for quantifying regional uptake in the different compartments of a phantom simulating the basal ganglia. These results indicate that the quantification method, which takes into account the blurring by the SPECT imaging device, promises to be perform better in the presence of background activity.

Mesh:

Substances:

Year:  2001        PMID: 11137793     DOI: 10.1016/s0895-6111(00)00045-8

Source DB:  PubMed          Journal:  Comput Med Imaging Graph        ISSN: 0895-6111            Impact factor:   4.790


  4 in total

Review 1.  SPECT imaging evaluation in movement disorders: far beyond visual assessment.

Authors:  Kosmas Badiavas; Elisavet Molyvda; Ioannis Iakovou; Magdalini Tsolaki; Kyriakos Psarrakos; Nikolaos Karatzas
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-12-02       Impact factor: 9.236

2.  Automatic semi-quantification of [123I]FP-CIT SPECT scans in healthy volunteers using BasGan version 2: results from the ENC-DAT database.

Authors:  Flavio Nobili; Mehrdad Naseri; Fabrizio De Carli; Susan Asenbaum; Jan Booij; Jacques Darcourt; Peter Ell; Ozlem Kapucu; Paul Kemp; Claus Svarer; Claus Varer; Silvia Morbelli; Marco Pagani; Osama Sabri; Klaus Tatsch; Livia Tossici-Bolt; Terez Sera; Tierry Vander Borght; Koen Van Laere; Andrea Varrone
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-12-12       Impact factor: 9.236

3.  Optimal ROI setting on the anatomically normalized I-123 FP-CIT images using high-resolution SPECT.

Authors:  Masanari Nonokuma; Yasuo Kuwabara; Kosuke Hida; Tomonobu Tani; Koichi Takano; Kengo Yoshimitsu
Journal:  Ann Nucl Med       Date:  2016-07-20       Impact factor: 2.668

4.  The basal ganglia matching tools package for striatal uptake semi-quantification: description and validation.

Authors:  Piero Calvini; Guido Rodriguez; Fabrizio Inguglia; Alessandro Mignone; Ugo Paolo Guerra; Flavio Nobili
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-02-08       Impact factor: 10.057