Reproducibility of ultrasonographic measures in internal jugular veins of normal subjects.

J I De Diego1, M P Prim, P Garcia-Raya, R Madero, J Gavilan.   

Abstract

OBJECTIVE: To assess the reproducibility of ultrasonographic quantitative parameters of internal jugular veins (IJV) in normal subjects.
MATERIAL AND METHODS: Thirty IJV of 15 normal volunteers were prospectively evaluated by means of duplex Doppler ultrasonography (US). Patency, presence of thrombosis, characteristics of the vein wall, compressibility, area of vein both in rest and during Valsalva maneuver, expiratory flow speed, Valsalva flow speed, jugular flow in each side, and total jugular flow were registered in all cases. Two measures were performed in each subject.
RESULTS: High reproducibility was encountered in jugular flow (R=0.95) and in area during Valsalva (R=0.90) in the left IJV. Low reproducibility was found in Valsalva flow speed of the left side (R=0.35). The remaining measurements had a good reproducibility (R=0.50-0.75).
CONCLUSIONS: The ultrasonographic parameters of IJV in normal subjects show an adequate grade of reproducibility. Thus, duplex Doppler US can be used as a reliable method for evaluation or comparison of IJV in different situations of future studies.

Entities:  

Mesh:

Year:  2001        PMID: 11137366     DOI: 10.1016/s0385-8146(00)00092-4

Source DB:  PubMed          Journal:  Auris Nasus Larynx        ISSN: 0385-8146            Impact factor:   1.863


  1 in total

1.  Reproducibility of cerebrospinal venous blood flow and vessel anatomy with the use of phase contrast-vastly undersampled isotropic projection reconstruction and contrast-enhanced MRA.

Authors:  E M Schrauben; K M Johnson; J Huston; A M Del Rio; S B Reeder; A Field; O Wieben
Journal:  AJNR Am J Neuroradiol       Date:  2013-11-28       Impact factor: 3.825

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.