Literature DB >> 11135288

Multiparameter analysis of human epithelial tumor cell lines by laser scanning cytometry.

A A Pollice1, C A Smith, K Brown, D L Farkas, J F Silverman, S E Shackney.   

Abstract

Laser scanning cytometry (LSC) is a relatively new slide-based technology developed for commercial use by CompuCyte (Cambridge, MA) for performing multiple fluorescence measurements on individual cells. Because techniques developed for performing four or more measurements on individual lymphoid cells based on light scatter as a triggering parameter for cell identification are not suitable for the identification of fixed epithelial tumor cells, an alternative approach is required for the analysis of such cells by LSC. Methods for sample preparation, event triggering, and the performance of multiple LSC measurements on disaggregated fixed human cells were developed using normal lymphocytes and two human breast cancer cell lines, JC-1939 and MCF-7, as test populations. Optimal conditions for individual cell identification by LSC were found to depend on several factors, including deposited cell density (cells per unit area), the dynamic range of probe fluorescence intensities, and intracellular distribution of the fluorescent probe. Sparsely deposited cells exhibited the least cell overlap and the brightest immunofluorescent staining. Major advantages of using DNA probes over a cytoplasmic immunofluorescent protein marker such as tubulin for event triggering are that the former exhibit greater fluorescence intensity within a relatively sharply demarcated nuclear region. The DNA-binding dye LDS-751 was found to be suboptimal for quantitative DNA measurements but useful as a triggering measurement that permits the performance of simultaneous fluorescein isothiocyanate-, phycoerythrin-, and indodicarbocyanine-based measurements on each cell. A major potential advantage of LSC over flow cytometry is the high yields of analyzable cells by LSC, permitting the performance of multiple panels of multicolor measurements on each tumor. In conclusion, we have developed and optimized a technique for performing multiple fluorescence measurements on fixed epithelial cells by LSC based on event triggering using the DNA-binding dye LDS 751. Although not ideal for quantitative measurements of cell DNA content, the large Stokes shift of this dye permits the performance of three or more additional fluorescence measurements on each cell.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11135288

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  4 in total

1.  Laser scanning cytometry: principles and applications.

Authors:  Piotr Pozarowski; Elena Holden; Zbigniew Darzynkiewicz
Journal:  Methods Mol Biol       Date:  2006

Review 2.  Biomedical Applications of Translational Optical Imaging: From Molecules to Humans.

Authors:  Daniel L Farkas
Journal:  Molecules       Date:  2021-11-02       Impact factor: 4.411

3.  Prognostic significance of S-phase fractions in peritumoral invading zone analyzed by laser scanning cytometry in patients with high-grade glioma: A preliminary study.

Authors:  Syoichi Nakajima; Ken Morii; Hitoshi Takahashi; Yukihiko Fujii; Ryuya Yamanaka
Journal:  Oncol Lett       Date:  2016-02-09       Impact factor: 2.967

4.  MUC1 regulates cyclin D1 gene expression through p120 catenin and β-catenin.

Authors:  X Liu; T C Caffrey; M M Steele; A Mohr; P K Singh; P Radhakrishnan; D L Kelly; Y Wen; M A Hollingsworth
Journal:  Oncogenesis       Date:  2014-06-30       Impact factor: 7.485

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.