Literature DB >> 11135090

Long-term clinical effects of a peritoneal dialysis fluid with less glucose degradation products.

B Rippe1, O Simonsen, O Heimbürger, A Christensson, B Haraldsson, G Stelin, L Weiss, F D Nielsen, S Bro, M Friedberg, A Wieslander.   

Abstract

BACKGROUND: Glucose degradation products (GDPs) are cytotoxic in vitro and potentially toxic in vivo during peritoneal dialysis (PD). We are presenting the results of a two-year randomized clinical trial of a new PD fluid, produced in a two-compartment bag and designed to minimize heat-induced glucose degradation while producing a near neutral pH. The effects of the new fluid over two years of treatment on membrane transport characteristics, ultrafiltration (UF) capacity, and effluent markers of peritoneal membrane integrity were investigated and compared with those obtained during treatment with a standard solution.
DESIGN: A two-group parallel design with 80 continuous ambulatory peritoneal dialysis patients was used. The patients were randomly assigned to either the new fluid (N = 40) or to a conventional one (N = 40), and were stratified with respect to age, diabetes, and time on PD. Peritoneal transport characteristics were assessed by the Personal Dialysis Capacity (PDCtrade mark) test at 1, 6, 12, 18, and 24 months after inclusion and by weighing the overnight bag daily. Infusion pain and handling were evaluated using a questionnaire. Peritoneal mesothelial and interstitial integrity were evaluated by analyzing overnight effluent dialysate concentrations of CA 125, hyaluronan (HA), procollagen-1-C-terminal peptide (PICP), and procollagen-3-N-terminal peptide (PIIINP) at 1, 6, 12, 18, and 24 months.
RESULTS: The handling of the new two-compartment bag was considered easy, and there were no indications of increased discomfort with the new system. Furthermore, no changes in peritoneal fluid or solute transport characteristics were observed during the study period for either fluid, and neither were there any differences with regard to peritonitis incidence. However, significantly higher dialysate CA 125 (73 +/- 41 vs. 25 +/- 18 U/mL), PICP (387 +/- 163 vs. 244 +/- 81 ng/mL), and PIIINP (50 +/- 24 vs. 29 +/- 13 ng/mL) and significantly lower concentrations of HA (395 +/- 185 vs. 530 +/- 298 ng/mL) were observed in the overnight effluent during treatment with the new fluid.
CONCLUSIONS: We conclude that the new fluid with a higher pH and less GDPs is safe and easy to use and has no negative effects on either the frequency of peritonitis or peritoneal transport characteristics as compared with conventional ones. Our results indicate that the new solution causes less mesothelial and interstitial damage than conventional ones; that is, it may be considered more biocompatible than a number of conventional PD solutions currently in use.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11135090     DOI: 10.1046/j.1523-1755.2001.00497.x

Source DB:  PubMed          Journal:  Kidney Int        ISSN: 0085-2538            Impact factor:   10.612


  35 in total

Review 1.  Glucose degradation products (GDP's) and peritoneal changes in patients on chronic peritoneal dialysis: will new dialysis solutions prevent these changes?

Authors:  Murali Krishnan; Paul Tam; George Wu; Andrzej Breborowicz; Dimitrios G Oreopoulos
Journal:  Int Urol Nephrol       Date:  2005       Impact factor: 2.370

2.  Is It Beneficial to Convert to a Neutral-pH Bicarbonate/Lactate-Buffered PD Solution in Long-Term CAPD Patients? A Single-Center Prospective Study.

Authors:  Tae-Hyun Yoo; Mi Jung Lee; Hyung Jung Oh; Jung Tak Park; Seung Hyeok Han; Shin-Wook Kang; Dae Suk Han
Journal:  Perit Dial Int       Date:  2015 May-Jun       Impact factor: 1.756

3.  Hyperbranched polyglycerol: a future alternative to polyglucose in peritoneal dialysis fluids?

Authors:  Bengt Rippe
Journal:  Perit Dial Int       Date:  2013 Jan-Feb       Impact factor: 1.756

Review 4.  Encapsulating peritoneal sclerosis: the state of affairs.

Authors:  Mario R Korte; Denise E Sampimon; Michiel G H Betjes; Raymond T Krediet
Journal:  Nat Rev Nephrol       Date:  2011-08-02       Impact factor: 28.314

5.  Time course of peritoneal function in automated and continuous peritoneal dialysis.

Authors:  Wieneke M Michels; Marion Verduijn; Alena Parikova; Elisabeth W Boeschoten; Dirk G Struijk; Friedo W Dekker; Raymond T Krediet
Journal:  Perit Dial Int       Date:  2012-04-02       Impact factor: 1.756

6.  Biocompatible Dialysis Solutions Preserve Peritoneal Mesothelial Cell and Vessel Wall Integrity. A Case-Control Study on Human Biopsies.

Authors:  Gloria del Peso; José Antonio Jiménez-Heffernan; Rafael Selgas; César Remón; Marta Ossorio; Antonio Fernández-Perpén; José Antonio Sánchez-Tomero; Antonio Cirugeda; Erika de Sousa; Pilar Sandoval; Raquel Díaz; Manuel López-Cabrera; María Auxiliadora Bajo
Journal:  Perit Dial Int       Date:  2015-10-16       Impact factor: 1.756

7.  Predictive model for delayed graft function based on easily available pre-renal transplant variables.

Authors:  Gianluigi Zaza; Pietro Manuel Ferraro; Gianpaolo Tessari; Silvio Sandrini; Maria Piera Scolari; Irene Capelli; Enrico Minetti; Loreto Gesualdo; Giampiero Girolomoni; Giovanni Gambaro; Antonio Lupo; Luigino Boschiero
Journal:  Intern Emerg Med       Date:  2014-08-28       Impact factor: 3.397

8.  Solutions for peritoneal dialysis in children: recommendations by the European Pediatric Dialysis Working Group.

Authors:  Claus Peter Schmitt; Sevcan A Bakkaloglu; Günter Klaus; Cornelis Schröder; Michel Fischbach
Journal:  Pediatr Nephrol       Date:  2011-03-31       Impact factor: 3.714

Review 9.  An update on peritoneal dialysis solutions.

Authors:  Elvia García-López; Bengt Lindholm; Simon Davies
Journal:  Nat Rev Nephrol       Date:  2012-02-21       Impact factor: 28.314

10.  Infusion fluids contain harmful glucose degradation products.

Authors:  Anna Bryland; Marcus Broman; Martin Erixon; Bengt Klarin; Torbjörn Lindén; Hans Friberg; Anders Wieslander; Per Kjellstrand; Claudio Ronco; Ola Carlsson; Gabriela Godaly
Journal:  Intensive Care Med       Date:  2010-04-16       Impact factor: 17.440