Literature DB >> 11133311

The accuracy of near infrared spectroscopy and imaging during focal changes in cerebral hemodynamics.

D A Boas1, T Gaudette, G Strangman, X Cheng, J J Marota, J B Mandeville.   

Abstract

Near infrared spectroscopy (NIRS) can detect changes in the concentrations of oxy-hemoglobin ([HbO]) and deoxy-hemoglobin ([Hb]) in tissue based upon differential absorption at multiple wavelengths. The common analysis of NIRS data uses the modified Beer-Lambert law, which is an empirical formulation that assumes global concentration changes. We used simulations to examine the errors that result when this analysis is applied to focal hemodynamic changes, and we performed simultaneous NIRS measurements during a motor task in adult humans and a neonate to evaluate the dependence of the measured changes on detector-probe geometry. For both simulations and in vivo measurements, the wide range of NIRS results was compared to an imaging analysis, diffuse optical tomography (DOT). The results demonstrate that relative changes in [HbO] and [Hb] cannot, in general, be quantified with NIRS. In contrast to that method, DOT analysis was shown to accurately quantify simulated changes in chromophore concentrations. These results and the general principles suggest that DOT can accurately measure changes in [Hb] and [HbO], but NIRS cannot accurately determine even relative focal changes in these chromophore concentrations. For the standard NIRS analysis to become more accurate for focal changes, it must account for the position of the focal change relative to the source and detector as well as the wavelength dependent optical properties of the medium. Copyright 2001 Academic Press.

Entities:  

Keywords:  Non-programmatic

Mesh:

Substances:

Year:  2001        PMID: 11133311     DOI: 10.1006/nimg.2000.0674

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  89 in total

1.  Hemodynamic evoked response of the sensorimotor cortex measured noninvasively with near-infrared optical imaging.

Authors:  Maria Angela Franceschini; Sergio Fantini; John H Thompson; Joseph P Culver; David A Boas
Journal:  Psychophysiology       Date:  2003-07       Impact factor: 4.016

Review 2.  Fiber optic in vivo imaging in the mammalian nervous system.

Authors:  Amit D Mehta; Juergen C Jung; Benjamin A Flusberg; Mark J Schnitzer
Journal:  Curr Opin Neurobiol       Date:  2004-10       Impact factor: 6.627

3.  On the geometry dependence of differential pathlength factor for near-infrared spectroscopy. I. Steady-state with homogeneous medium.

Authors:  Daqing Piao; Randall L Barbour; Harry L Graber; Daniel C Lee
Journal:  J Biomed Opt       Date:  2015-10       Impact factor: 3.170

4.  Tutorial on platform for optical topography analysis tools.

Authors:  Stephanie Sutoko; Hiroki Sato; Atsushi Maki; Masashi Kiguchi; Yukiko Hirabayashi; Hirokazu Atsumori; Akiko Obata; Tsukasa Funane; Takusige Katura
Journal:  Neurophotonics       Date:  2016-01-11       Impact factor: 3.593

Review 5.  IRON fMRI measurements of CBV and implications for BOLD signal.

Authors:  Joseph B Mandeville
Journal:  Neuroimage       Date:  2012-01-16       Impact factor: 6.556

6.  Extraction of cognitive activity-related waveforms from functional near-infrared spectroscopy signals.

Authors:  Ceyhun Burak Akgül; Ata Akin; Bülent Sankur
Journal:  Med Biol Eng Comput       Date:  2006-10-24       Impact factor: 2.602

Review 7.  Near infrared spectroscopy: finding utility in malignant hemispheric stroke.

Authors:  Raphael Carandang; Derk W Krieger
Journal:  Neurocrit Care       Date:  2007       Impact factor: 3.210

8.  Double-layer estimation of intra- and extracerebral hemoglobin concentration with a time-resolved system.

Authors:  Louis Gagnon; Claudine Gauthier; Rick D Hoge; Frédéric Lesage; Juliette Selb; David A Boas
Journal:  J Biomed Opt       Date:  2008 Sep-Oct       Impact factor: 3.170

9.  Temporal profiles and 2-dimensional oxy-, deoxy-, and total-hemoglobin somatosensory maps in rat versus mouse cortex.

Authors:  Neal Prakash; Jonathan D Biag; Sameer A Sheth; Satoshi Mitsuyama; Jeremy Theriot; Chaithanya Ramachandra; Arthur W Toga
Journal:  Neuroimage       Date:  2007-05-21       Impact factor: 6.556

10.  High-density diffuse optical tomography of term infant visual cortex in the nursery.

Authors:  Steve M Liao; Silvina L Ferradal; Brian R White; Nicholas Gregg; Terrie E Inder; Joseph P Culver
Journal:  J Biomed Opt       Date:  2012-08       Impact factor: 3.170

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.