Literature DB >> 11132985

Anderson type II fracture of the odontoid process: results of anterior screw fixation.

H ElSaghir1, H Böhm.   

Abstract

Controversy exists in the literature regarding the adequacy of one or two screws for direct fixation of the odontoid process. Proponents of the two-screw technique believe that a single screw is not adequate to stabilize the fracture. Conversely, the insertion of two 3.5-mm screws in the medullary cavity of the odontoid process is technically difficult and can jeopardize the surface area left for fracture healing. The authors conducted a prospective study of 30 cases with Anderson type II fracture of the odontoid process treated by direct anterior fixation using the two-screw technique. The screws used were 2.7-mm cortical screws manufactured from titanium. Two C-arms were used to control reduction of the displaced fracture and for its direct anterior stabilization. The operation was performed with the patients under general anesthesia. The anterolateral incision was made at the level of C4 to facilitate exposure of the C2-C3 disk and for fracture fixation. No evidence of nonunion was encountered. Spontaneous fusion of the C2-C3 segment was found in one case. Limitation of rotation of the cervical spine was a subjective description in a single case. No major complications were attributed to the surgical technique. The two 2.7-mm self-tapping titanium cortical screws provided adequate stability for fixation of type II odontoid fractures.

Entities:  

Mesh:

Year:  2000        PMID: 11132985     DOI: 10.1097/00002517-200012000-00011

Source DB:  PubMed          Journal:  J Spinal Disord        ISSN: 0895-0385


  12 in total

1.  Management of odontoid fractures with percutaneous anterior odontoid screw fixation.

Authors:  Yong-Long Chi; Xiang-Yang Wang; Hua-Zi Xu; Yan Lin; Qi-Shan Huang; Fang-Min Mao; Wen-Fei Ni; Sheng Wang; Li-Yang Dai
Journal:  Eur Spine J       Date:  2007-03-03       Impact factor: 3.134

2.  One-screw fixation provides similar stability to that of two-screw fixation for type II dens fractures.

Authors:  Gang Feng; Robert Wendlandt; Sebastian Spuck; Arndt P Schulz
Journal:  Clin Orthop Relat Res       Date:  2012-05-15       Impact factor: 4.176

Review 3.  The impact of odontoid screw fixation techniques on screw-related complications and fusion rates: a systematic review and meta-analysis.

Authors:  Ivan Lvov; Andrey Grin; Aleksandr Talypov; Ivan Godkov; Anton Kordonskiy; Ulugbek Khushnazarov; Vladimir Smirnov; Vladimir Krylov
Journal:  Eur Spine J       Date:  2020-06-15       Impact factor: 3.134

4.  Efficacy of anterior odontoid screw fixation in the elderly patient: a CT-based biometrical analysis of odontoid fractures.

Authors:  Michael Mayer; Juliane Zenner; Alexander Auffarth; Jörg Atzwanger; Franz Romeder; Wolfgang Hitzl; Stefan Lederer; Herbert Resch; Heiko Koller
Journal:  Eur Spine J       Date:  2011-05-24       Impact factor: 3.134

5.  A meta-analysis of the fusion rate from surgical treatment for odontoid factures: anterior odontoid screw versus posterior C1-C2 arthrodesis.

Authors:  Ye Shen; Jinhao Miao; Chao Li; Lei Fang; Samantha Cao; Ming Zhang; Jianhua Yan; Yong Kuang
Journal:  Eur Spine J       Date:  2015-03-25       Impact factor: 3.134

6.  Morphometric analysis of the odontoid process: using computed tomography--in the Greek population.

Authors:  D S Korres; J Lazaretos; J Papailiou; E Kyriakopoulos; D Chytas; N E Efstathopoulos; V S Nikolaou
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-11-11

7.  Computerized Tomography-Based Morphometric Analysis of Odontoid in 100 Egyptian Patients.

Authors:  Nirmal D Patil; Mohammad Essam; Raafat Kamal Ragab; Hesham Elsaghir
Journal:  Int J Spine Surg       Date:  2020-02-29

8.  CT based evaluation of odontoid morphology in the Indian population.

Authors:  Arvind G Kulkarni; Siddharth M Shah; Ruchira A Marwah; Prasad B Hanagandi; Inder R Talwar
Journal:  Indian J Orthop       Date:  2013-05       Impact factor: 1.251

9.  An in vitro biomechanical evaluation of an expansive double-threaded bi-directional compression screw for fixation of type II odontoid process fractures: A SQUIRE-compliant article.

Authors:  Ning Liu; Li Tian; Rong-Xian Jiang; Chao Xu; Lei Shi; Wei Lei; Yang Zhang
Journal:  Medicine (Baltimore)       Date:  2017-04       Impact factor: 1.889

10.  Pooled analysis of non-union, re-operation, infection, and approach related complications after anterior odontoid screw fixation.

Authors:  Nai-Feng Tian; Xu-Qi Hu; Li-Jun Wu; Xin-Lei Wu; Yao-Sen Wu; Xiao-Lei Zhang; Xiang-Yang Wang; Yong-Long Chi; Fang-Min Mao
Journal:  PLoS One       Date:  2014-07-24       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.