Literature DB >> 11131496

Objective quantification of the motion of soft tissues in the orbit.

M D Abràmoff1, W J Niessen, M A Viergever.   

Abstract

Orbital soft-tissue motion analysis aids in the localization and diagnosis of orbital disorders. A technique has been developed to objectively quantify and visualize motion in the orbit during gaze. T1-weighted MR volume sequences are acquired during gaze and soft-tissue motion is quantified using optical flow techniques. The flow field is visualized using color-coding: orientation of the flow vector is coded by hue and magnitude by saturation of the pixel. Current clinical circumstances limit MR image acquisition to short sequences and short acquisition times. The effect of these limitations on the performance of optical flow computation has been studied for four representative optical flow algorithms: on short (nine frames) and long (21 frames) simulated sequences of rotation of a magnetic resonance (MR) imaged object, on short measured MR sequences of controlled rotation of the same object and on short MR sequences of motion in the orbit. On the short simulated and motion-controlled sequences, the Lucas and Kanade algorithm showed the best performance with respect to both accuracy and robustness. These motion estimates were accurate to within 20%. Motion in the orbit ranged between 0.05 and 0.25 mm/degree gaze. Color-coding was found to be attractive as a visualization technique, because it shows both magnitude and orientation of all flow vectors without cluttering.

Entities:  

Mesh:

Year:  2000        PMID: 11131496     DOI: 10.1109/42.887614

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  8 in total

1.  Mechanical responses of the organ of corti to acoustic and electrical stimulation in vitro.

Authors:  Dylan K Chan; A J Hudspeth
Journal:  Biophys J       Date:  2005-09-16       Impact factor: 4.033

2.  In vitro contraction protects against palmitate-induced insulin resistance in C2C12 myotubes.

Authors:  Stephan Nieuwoudt; Anny Mulya; Ciarán E Fealy; Elizabeth Martelli; Srinivasan Dasarathy; Sathyamangla V Naga Prasad; John P Kirwan
Journal:  Am J Physiol Cell Physiol       Date:  2017-08-23       Impact factor: 4.249

3.  Multimodal retinal vessel segmentation from spectral-domain optical coherence tomography and fundus photography.

Authors:  Zhihong Hu; Meindert Niemeijer; Michael D Abràmoff; Mona K Garvin
Journal:  IEEE Trans Med Imaging       Date:  2012-06-29       Impact factor: 10.048

4.  Direction of actin flow dictates integrin LFA-1 orientation during leukocyte migration.

Authors:  Pontus Nordenfelt; Travis I Moore; Shalin B Mehta; Joseph Mathew Kalappurakkal; Vinay Swaminathan; Nobuyasu Koga; Talley J Lambert; David Baker; Jennifer C Waters; Rudolf Oldenbourg; Tomomi Tani; Satyajit Mayor; Clare M Waterman; Timothy A Springer
Journal:  Nat Commun       Date:  2017-12-11       Impact factor: 14.919

5.  Spindle-F-actin interactions in mitotic spindles in an intact vertebrate epithelium.

Authors:  Angela M Kita; Zachary T Swider; Ivan Erofeev; Mary C Halloran; Andrew B Goryachev; William M Bement
Journal:  Mol Biol Cell       Date:  2019-05-15       Impact factor: 4.138

6.  Revisiting the NASA surface tension driven convection experiments.

Authors:  Yohan Sequeira; Abhradeep Maitra; Anupam Pandey; Sunghwan Jung
Journal:  NPJ Microgravity       Date:  2022-02-18       Impact factor: 4.415

7.  Visualization of Sliding and Deformation of Orbital Fat During Eye Rotation.

Authors:  Gijsbert J Hötte; Peter J Schaafsma; Charl P Botha; Piotr A Wielopolski; Huibert J Simonsz
Journal:  Transl Vis Sci Technol       Date:  2016-07-29       Impact factor: 3.283

8.  Automated measurement of fast mitochondrial transport in neurons.

Authors:  Kyle E Miller; Xin-An Liu; Sathyanarayanan V Puthanveettil
Journal:  Front Cell Neurosci       Date:  2015-11-03       Impact factor: 5.505

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.