Literature DB >> 11131056

Doppler US gating of cardiac MR imaging.

J M Rubin1, J B Fowlkes, M R Prince, R T Rhee, T L Chenevert.   

Abstract

RATIONALE AND
OBJECTIVES: Electrocardiographic (ECG) gating of cardiac magnetic resonance (MR) imaging has been problematic for many reasons. The purpose of this study was to demonstrate the feasibility of using Doppler ultrasound (US) gating, either directly off the moving cardiac wall or the systolic upstroke of the arterial signal from the great vessels in neck, in alternative gating modes.
MATERIALS AND METHODS: A 2.5-MHz, range-gated Doppler US device was used with A-mode guidance for gating directly off left ventricular wall motion. A 4- or 8.1-MHz, continuous-wave (CW) Doppler US device was used for gating off the systolic upstroke from the great vessels in the neck. The subject undergoing imaging held the transducer against his chest for range-gated Doppler US and against his neck for 8.1-MHz CW Doppler US. The 4-MHz transducer was strapped to the subject's neck. Modified Doppler signals were fed back into the gating circuitry of the MR imager to achieve cardiac synchrony.
RESULTS: Cardiac gating was achieved by using both the range-gated technique directly off the cardiac wall and the CW method off blood flow from the great vessels. Problems occurred with radiofrequency shielding during the range-gated method; however, these problems were almost completely removed by use of the CW Doppler probes.
CONCLUSION: Doppler US gating of MR images is possible and potentially could overcome many shortcomings of ECG gating. Subsequent embodiments of the technique will require improved radiofrequency shielding in the range-gated technique.

Entities:  

Mesh:

Year:  2000        PMID: 11131056     DOI: 10.1016/s1076-6332(00)80065-3

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  9 in total

1.  Progress in multimodality imaging: truly simultaneous ultrasound and magnetic resonance imaging.

Authors:  Laura Curiel; Rajiv Chopra; Kullervo Hynynen
Journal:  IEEE Trans Med Imaging       Date:  2007-12       Impact factor: 10.048

2.  Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla.

Authors:  Tobias Frauenrath; Fabian Hezel; Wolfgang Renz; Thibaut de Geyer d'Orth; Matthias Dieringer; Florian von Knobelsdorff-Brenkenhoff; Marcel Prothmann; Jeanette Schulz Menger; Thoralf Niendorf
Journal:  J Cardiovasc Magn Reson       Date:  2010-11-16       Impact factor: 5.364

3.  Prospective ECG-gated mouse cardiac imaging with a 34-MHz annular array transducer.

Authors:  Jeffrey A Ketterling; Orlando Aristizábal
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-07       Impact factor: 2.725

4.  Ultrasound-based sensors to monitor physiological motion.

Authors:  Bruno Madore; Frank Preiswerk; Jeremy S Bredfeldt; Shenyan Zong; Cheng-Chieh Cheng
Journal:  Med Phys       Date:  2021-06-07       Impact factor: 4.506

5.  ECG-based gating in ultra high field cardiovascular magnetic resonance using an independent component analysis approach.

Authors:  Johannes W Krug; Georg Rose; Gari D Clifford; Julien Oster
Journal:  J Cardiovasc Magn Reson       Date:  2013-11-19       Impact factor: 5.364

6.  Initial evaluation of prospective cardiac triggering using photoplethysmography signals recorded with a video camera compared to pulse oximetry and electrocardiography at 7T MRI.

Authors:  Nicolai Spicher; Markus Kukuk; Stefan Maderwald; Mark E Ladd
Journal:  Biomed Eng Online       Date:  2016-11-24       Impact factor: 2.819

7.  Scattering matrix imaging pulse design for real-time respiration and cardiac motion monitoring.

Authors:  Sven H F Jaeschke; Matthew D Robson; Aaron T Hess
Journal:  Magn Reson Med       Date:  2019-07-17       Impact factor: 4.668

8.  Doppler ultrasound cardiac gating of intracranial flow at 7T.

Authors:  Karin Markenroth Bloch; Fabian Kording; Johannes Töger
Journal:  BMC Med Imaging       Date:  2020-12-09       Impact factor: 1.930

9.  Doppler Ultrasound Triggering for Cardiovascular MRI at 3T in a Healthy Volunteer Study.

Authors:  Fabian Kording; Jin Yamamura; Gunnar Lund; Friedrich Ueberle; Caroline Jung; Gerhard Adam; Bjoern Philip Schoennagel
Journal:  Magn Reson Med Sci       Date:  2016-03-21       Impact factor: 2.471

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.