Literature DB >> 11130482

Hybrid external fixation in high-energy elbow fractures: a modular system with a promising future.

A Lerner1, S Stahl, H Stein.   

Abstract

BACKGROUND: Severe, high-energy, periarticular elbow injuries producing a "floating joint" are a major surgical challenge. Their reconstruction and rehabilitation are not well documented. Therefore, the following reports our experience with treating such injuries caused by war wounds.
METHODS: Seven adults with compound open peri- and intra-articular elbow fractures were treated in hybrid ring tubular fixation frames. After debridement, bone stabilization, and neurovascular reconstructions, early controlled daily movements were started in the affected joint.
RESULTS: These seven patients had together seven humeral, five radial, and six ulnar fractures. All fractures united at a median time of 180 days. No deep infection developed. The functional end results assessed by the Khalfayan functional score were excellent in two, good in one, and fair in four of these severely mangled upper extremities. None was amputated.
CONCLUSIONS: The Mangled Extremity Severity Score has been shown to be unable to provide a reliable assessment for severe high-energy limb injuries surgically managed with the modular hybrid thin wire tubular external fixation system. This hybrid system is a very useful addition to the surgical armamentarium of orthopedic trauma surgeons. It both allows complex surgical reconstructions and reduces the incidence of deep infections in these heavily contaminated injuries. The hybrid circular (thin wire) external fixation system is very modular and may provide secure skeletal stabilization even in cases of severely comminuted juxta-articular fractures on both sides of the elbow joint (floating elbow) with severe damage to soft tissues. This fixation system allows individual fixation of forearm bone fractures, thus allowing the preservation of pronation-supination movements.

Entities:  

Mesh:

Year:  2000        PMID: 11130482     DOI: 10.1097/00005373-200012000-00007

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  3 in total

1.  Analysis of complications after a floating elbow injury.

Authors:  Verónica Jiménez-Díaz; Ismael Auñón-Martín; Carlos Olaya-González; Miguel Aroca-Peinado; David Cecilia-López; Pedro Caba-Doussoux
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-10-13

2.  Fractures of the distal humerus in elderly patients treated with a ring fixator.

Authors:  Alon Burg; Michael Berenstein; Joel Engel; Tal Luria; Moshe Salai; Israel Dudkiewicz; Steven Velkes
Journal:  Int Orthop       Date:  2010-02-06       Impact factor: 3.075

3.  Avoidance of external fixation pin induced rotational stiffness in the forearm; a cadaver study of soft tissue displacement relative to the varying position of radius and ulna fixation.

Authors:  Pavel Nikolaevich Kulesh; Matt D A Fletcher; Leonid N Solomin
Journal:  SICOT J       Date:  2015-05-29
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.