Literature DB >> 11129511

Effect of mode of delivery on neonatal outcome of twins with birthweight under 1500 g.

S M Ziadeh1, L F Badria.   

Abstract

OBJECTIVE: The purpose of this retrospective study was to evaluate. The mode of delivery on neonatal outcome of twins weighing <1500 g.
METHODS: We reviewed the effect of birth order, presentation, and method of delivery on neonatal outcome in twin gestation under 1500 g at Princess Badeea' Teaching Hospital in North Jordan over the 6-years from 1994 to 1999.
RESULTS: During the study period, there were 51475 deliveries of which 695 were twin gestations. One hundred and eight (108) sets of twins weighing <1500 g were included in the study (15.5%), of which 41 were in vertex-vertex presentation, 40 in vertex-nonvertex, and 27 with first twin in nonvertex presentation. The second twin pregnancies characterized by a higher incidence of respiratory distress syndrome (82 vs. 70%; p=0.02) more neonatal mortality (23 vs. 17.6%), and lower Apgar score at 1 and 5 min. Cesarean delivery for vertex-vertex presentation did not improve the neonatal outcome. Rather, the incidence of RDS was significantly greater in this group delivered by cesarean section (65.6 vs. 42%, p=0.012). For nonvertex presentation, those delivered by cesarean section had a lower incidence of neonatal mortality.
CONCLUSION: We concluded there was no advantage for cesarean delivery that could be demonstrated after multivariate analysis to correct the differences in birthweight between the groups. Therefore, the differences in the neonatal outcome of non vertex twins presentation accounted for the differences in birthweight, rather than in mode of delivery.

Entities:  

Mesh:

Year:  2000        PMID: 11129511     DOI: 10.1007/s004040000096

Source DB:  PubMed          Journal:  Arch Gynecol Obstet        ISSN: 0932-0067            Impact factor:   2.344


  4 in total

1.  Birth order, gestational age, and risk of delivery related perinatal death in twins: retrospective cohort study.

Authors:  Gordon C S Smith; Jill P Pell; Richard Dobbie
Journal:  BMJ       Date:  2002-11-02

2.  No relationship between mode of delivery and neonatal mortality and neurodevelopment in very low birth weight infants aged two years.

Authors:  Jia-Jun Zhu; Ying-Ying Bao; Guo-Lian Zhang; Li-Xin Ma; Ming-Yuan Wu
Journal:  World J Pediatr       Date:  2014-08-15       Impact factor: 2.764

Review 3.  What is the safest mode of delivery for extremely preterm cephalic/non-cephalic twin pairs? A systematic review and meta-analyses.

Authors:  Catherine Dagenais; Anne-Mary Lewis-Mikhael; Marinela Grabovac; Amit Mukerji; Sarah D McDonald
Journal:  BMC Pregnancy Childbirth       Date:  2017-11-29       Impact factor: 3.007

4.  Risk Factors of Respiratory Diseases Among Neonates in Neonatal Intensive Care Unit of Qena University Hospital, Egypt.

Authors:  Khaled A Abdel Baseer; Mostafa Mohamed; Eman A Abd-Elmawgood
Journal:  Ann Glob Health       Date:  2020-02-26       Impact factor: 2.462

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.