Literature DB >> 11128302

A mixed-encoding genetic algorithm with beam constraint for conformal radiotherapy treatment planning.

X Wu1, Y Zhu.   

Abstract

In this paper we propose a new hierarchical evolutionary algorithm that combines binary encoding and floating-point encoding to automatically select the beam directions and determine the weights of the selected beams. With traditional optimization methods the beam directions are fixed a priori by the operator in recognition of the fact that computer selection of beam directions is a difficult problem. In this investigation, we used a hybrid-encoding scheme. The binary encoding part of each chromosome was used to select the beam directions, and its corresponding floating-point encoding part of the same chromosome was used to determine the weights of those selected beams. Before beginning the optimization process, we set a constraint on the number of the beam directions we wanted in the final solution. We present three examples to verify this method. These examples differ with each other in tumor sites, problem sizes, and optimization parameters. Three-dimensional optimization results and statistical data showed that this method is feasible. We think this method can be easily extended to solve more complex target problems (such as nonconvex target problems).

Entities:  

Mesh:

Year:  2000        PMID: 11128302     DOI: 10.1118/1.1319377

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

Review 1.  The Applications of Genetic Algorithms in Medicine.

Authors:  Ali Ghaheri; Saeed Shoar; Mohammad Naderan; Sayed Shahabuddin Hoseini
Journal:  Oman Med J       Date:  2015-11

2.  Optimization of beam angles for intensity modulated radiation therapy treatment planning using genetic algorithm on a distributed computing platform.

Authors:  Daryl P Nazareth; Stephen Brunner; Matthew D Jones; Harish K Malhotra; Mohammad Bakhtiari
Journal:  J Med Phys       Date:  2009-07

3.  An experimental investigation on the effect of beam angle optimization on the reduction of beam numbers in IMRT of head and neck tumors.

Authors:  V K Sathiya Narayanan; R Vaitheeswaran; Janhavi R Bhangle; Sumit Basu; Vikram Maiya; Bhooshan Zade
Journal:  J Appl Clin Med Phys       Date:  2012-07-05       Impact factor: 2.102

4.  Determination of optimal number of beams in direct machine parameter optimization-based intensity modulated radiotherapy for head and neck cases.

Authors:  Vaitheeswaran Ranganathan; K J Maria Das
Journal:  J Med Phys       Date:  2016 Apr-Jun
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.