Validation of the microbiological methods hygicult dipslide, contact plate, and swabbing in surface hygiene control: a Nordic collaborative study.

S Salo1, A Laine, T Alanko, A M Sjöberg, G Wirtanen.   

Abstract

A collaborative study on total aerobic bacterial count was conducted to validate the Hygicult TPC dipslide against contact plates and swabbing, using stainless-steel surfaces artificially contaminated with different microbes at various levels. Twelve laboratories took part in the validation procedure. The total number of collaborative samples was 108. The microbial level in each sample was assessed in triplicate using the 3 above-mentioned methods under 3 different incubation conditions (at 25 +/- 1 degrees C for 48 and 72 h and at 30 +/- 1 degrees C for 48 h). Surface sampling methods detached 25-30% at the lowest (theoretical yield, 1.4 cfu/cm2), 18-20% at the middle (theoretical yield, 10.7 cfu/cm2), and 16-21% at the highest (theoretical yield, 43.6 cfu/cm2) levels of microbes from the test surfaces. The percentage of acceptable results after removing outliers was 89%. Repeatability standard deviations ranged from 27.2 to 74.6% and reproducibility standard deviations ranged from 42.1 to 97.5%. There were no significant differences between results obtained at different incubation temperatures (25 and 30 degrees C) or incubation times (48 and 72 h) for all 3 methods. The Hygicult TPC dipslide, contact plate, and swabbing methods gave similar results at all 3 microbial levels tested: 0.35-0.43 cfu/cm2 at the lowest level, 1.9-2.2 cfu/cm2 at the middle level, and 7.1-9.1 cfu/cm2 at the highest level.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11128138

Source DB:  PubMed          Journal:  J AOAC Int        ISSN: 1060-3271            Impact factor:   1.913


  4 in total

1.  Assessment of interplay between UV wavelengths, material surfaces and food residues in open surface hygiene validation.

Authors:  Stephen Abban; Mogens Jakobsen; Lene Jespersen
Journal:  J Food Sci Technol       Date:  2013-01-25       Impact factor: 2.701

2.  Validation of dipslides as a tool for environmental sampling in a real-life hospital setting.

Authors:  T Ibfelt; C Foged; L P Andersen
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2013-11-20       Impact factor: 3.267

Review 3.  Hospital surface disinfection using ultraviolet germicidal irradiation technology: A review.

Authors:  Robert Scott; Lovleen Tina Joshi; Conor McGinn
Journal:  Healthc Technol Lett       Date:  2022-05-28

4.  Influence of clipping on bacterial contamination of canine arthrocentesis sites before and after skin preparation.

Authors:  Justin M Lavallée; Cindy Shmon; Hugues Beaufrère; Manuel Chirino-Trejo; Kathleen Linn
Journal:  Vet Surg       Date:  2020-06-09       Impact factor: 1.495

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.