Rapid small-animal dual-energy X-ray absorptiometry using digital radiography.

D W Holdsworth1, M M Thornton, D Drost, P H Watson, L J Fraher, A B Hodsman.   

Abstract

Although dual-energy X-ray absorptiometry (DEXA) is an established technique for clinical assessment of areal bone mineral density (BMD), the spatial resolution, signal-to-noise ratio, scan time, and availability of clinical DEXA systems may be limiting factors for small-animal investigations using a large number of specimens. To avoid these limitations, we have implemented a clinical digital radiography system to perform rapid area DEXA analysis on in vitro rat bone specimens. A crossed step-wedge (comprised of epoxy-based materials that mimic the radiographic properties of tissue and bone) was used to calibrate the system. Digital radiographs of bone specimens (pelvis, spine, femur, and tibia from sham-ovariectomized [SHAM] and ovariectomized [OVX] rats) were obtained at 40 kilovolt peak (kVp) and 125 kVp, and the resulting areal BMD values were compared with those obtained with a clinical fan-beam DEXA system (Hologics QDR 4500). Our investigation indicates that the cross-wedge calibrated (CWC) DEXA technique provides high-precision measurements of bone mineral content (BMC; CV = 0.6%) and BMD (CV = 0.8%) within a short acquisition time (<30 s). Areal BMD measurements reported by the CWC-DEXA system are within 8.5% of those reported by a clinical fan-beam scanner, and BMC values are within 5% of the known value of test specimens. In an in vivo application, the CWC-DEXA system is capable of reporting significant differences between study groups (SHAM and OVX) that are not reported by a clinical fan-beam DEXA system, because of the reduced variance and improved object segmentation provided by the CWC-DEXA system.

Entities:  

Mesh:

Year:  2000        PMID: 11127209     DOI: 10.1359/jbmr.2000.15.12.2451

Source DB:  PubMed          Journal:  J Bone Miner Res        ISSN: 0884-0431            Impact factor:   6.741


  2 in total

1.  Volumetric analysis of mice lungs in a clinical magnetic resonance imaging scanner.

Authors:  Johannes T Heverhagen; Horst K Hahn; Michael Wegmann; Udo Herz; Chastity D Shaffer Whitaker; Volker Matschl; Heiko Alfke
Journal:  MAGMA       Date:  2004-10-05       Impact factor: 2.310

2.  Novel insight into stem cell trafficking in dystrophic muscles.

Authors:  Andrea Farini; Chiara Villa; Adrian Manescu; Fabrizio Fiori; Alessandra Giuliani; Paola Razini; Clementina Sitzia; Giulia Del Fraro; Marzia Belicchi; Mirella Meregalli; Franco Rustichelli; Yvan Torrente
Journal:  Int J Nanomedicine       Date:  2012-06-20
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.