Literature DB >> 11124486

An improved echocardiographic rejection-surveillance strategy following pediatric heart transplantation.

G J Putzer1, D Cooper, C Keehn, A Asante-Korang, M M Boucek, R J Boucek.   

Abstract

BACKGROUND: The unique demands of cardiac transplantation in infancy have led to non-invasive rejection-surveillance strategies. ECHO-A is a multiparametric, two-dimensionally guided, M-mode analysis algorithm that assigns an empirically derived score for deviations of recipient parameters to age-adjusted, population-based normal values. A cumulative ECHO-A score > or =4 is highly predictive of endomyocardial biopsy Grade > or =3 and of cellular rejection.
METHODS: This study determined whether modifying ECHO-A to score for deviations of recipient parameters from the recipient's baseline would improve the predictive power of ECHO-A. We reanalyzed 701 consecutive echocardiograms of 18 pediatric cardiac transplant recipients (median age at transplantation, 142 days) and based scoring on significant (Z score > or =1) deviation from the patients' baseline means (ECHO-B).
RESULTS: Eight episodes of treated rejection occurred during the first year after transplantation (median, 1.4 years). Approximately 10% (72) of the analyses had ECHO-A scores > or =4 that were not associated with treated rejection and were considered false positives. We identified parameters that contributed to the false-positive evaluations and calculated patient-specific baseline mean +/- standard deviation. The ECHO-B, in comparison with ECHO-A, decreased the number of false positives from 72 to 10, increased specificity from 90% to 99%, and increased the positive predictive value about 4-fold (10% to 44%). With treated rejection episodes, ECHO-B increased ECHO-A scores in 7 of 8 recipients and increased the mean score from 6 to 8.
CONCLUSIONS: analysis algorithm based on change from baseline improved the positive predictive power without reducing the negative predictive value of multiparametric quantitative analyses of echocardiograms following pediatric heart transplantation.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11124486     DOI: 10.1016/s1053-2498(00)00214-x

Source DB:  PubMed          Journal:  J Heart Lung Transplant        ISSN: 1053-2498            Impact factor:   10.247


  6 in total

1.  Right Ventricular Dysfunction as an Echocardiographic Measure of Acute Rejection Following Heart Transplantation in Children.

Authors:  Sanjeev Aggarwal; Jennifer Blake; Swati Sehgal
Journal:  Pediatr Cardiol       Date:  2016-11-23       Impact factor: 1.655

Review 2.  Multi-modal imaging of the pediatric heart transplant recipient.

Authors:  Jonathan H Soslow; Margaret M Samyn
Journal:  Transl Pediatr       Date:  2019-10

3.  Changes in circumferential strain can differentiate pediatric heart transplant recipients with and without graft rejection.

Authors:  Katerina Boucek; Ali Burnette; Heather Henderson; Andrew Savage; Shahryar M Chowdhury
Journal:  Pediatr Transplant       Date:  2021-11-25

Review 4.  Postoperative care of the transplanted patient.

Authors:  Kurt R Schumacher; Robert J Gajarski
Journal:  Curr Cardiol Rev       Date:  2011-05

5.  Serial assessment of right ventricular function can detect acute cellular rejection in children with heart transplantation.

Authors:  Lindsay Arthur; Kenneth Knecht; Jennifer Ferry; Debby Grigsby; Horace Spencer; Dala Zakaria
Journal:  Pediatr Transplant       Date:  2022-01-18

Review 6.  Diagnostic performance of echocardiography for the detection of acute cardiac allograft rejection: a systematic review and meta-analysis.

Authors:  Wei Lu; Jun Zheng; Xudong Pan; Lizhong Sun
Journal:  PLoS One       Date:  2015-03-30       Impact factor: 3.240