Safe and efficient gene transfer into porcine hepatocytes using Sendai virus-cationic liposomes for bioartificial liver support.

Y Kawashita1, A Ohtsuru, H Fujioka, Y Kamohara, Y Kawazoe, N Sugiyama, S Eguchi, H Kuroda, J Furui, S Yamashita, Y Kaneda, T Kanematsu.   

Abstract

Establishment of a bioartificial liver support system using genetically modified hepatocytes is a potential approach to improve the treatment of severe liver failure. We describe the development of an efficient ex vivo method of gene transfer into a large number of porcine hepatocytes using hemagglutinating virus of Japan (HVJ)-liposome. The transfection efficiency of HVJ-liposome into isolated porcine hepatocytes attached to microcarrier beads was evaluated by beta-galactosidase (beta-gal) staining, fluorescence activated cell sorting analysis for beta-gal and luciferase assay, respectively. To examine the function and cellular damage of transduced hepatocytes, we used enzyme-linked immunosorbent assay for porcine albumin synthesis, lidocaine clearance test (P-450 activity), aspartate aminotransferase, and lactic dehydrogenase release assays. The optimal conditions for gene transfer into the beads-attached hepatocytes using HVJ-liposome included 4 microg of deoxyribonucleic acid with 200 microg of lipid/2 x 105 cells and exposure duration of 90 min. Under these conditions, beta-gal and luciferase genes were transduced to 2.5 x 108 isolated porcine hepatocytes following attachment to the beads. Positive beta-gal staining was observed in more than 30% of the beads-attached hepatocytes. The gene transfer activity of HVJ-liposome method determined by luciferase activities was about 100-fold of that of the lipofection method. Transfected porcine hepatocytes remained functional without any significant cell damage. Our results demonstrated that HVJ-liposome mediated gene transfer into microcarrier-attached porcine hepatocytes is an efficient and nontoxic method suitable for a bioartificial liver support sytem.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11121972     DOI: 10.1046/j.1525-1594.2000.06631.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  1 in total

1.  TECA hybrid artificial liver support system in treatment of acute liver failure.

Authors:  Y L Xue; S F Zhao; Y Luo; X J Li; Z P Duan; X P Chen; W G Li; X Q Huang; Y L Li; X Cui; D G Zhong; Z Y Zhang; Z Q Huang
Journal:  World J Gastroenterol       Date:  2001-12       Impact factor: 5.742

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.