Literature DB >> 11121543

Assessment of synthetic peptides for hepatitis A diagnosis using biosensor technology.

M J Gómara1, G Ercilla, M A Alsina, I Haro.   

Abstract

In the present work we demonstrate the application of a commercial biosensor instrument (BIACORE 1000, Biacore AB, Uppsala) for the detection of antibodies against the hepatitis A virus (HAV) in human serum samples using linear and branched synthetic peptides related to the VP3 capsid protein of HAV. We also studied the conformation of the synthetic peptides by circular dichroism (CD) in order to analyse the changes in secondary structure of the constructs that could influence their recognition by antibodies. Linear and dimeric VP3(110-121) multiple antigen peptides (MAP) were the most sensitive and appropriate for serological studies of serum from HAV infected patients using BIACORE. Immobilization of tetrameric MAPs via amine groups apparently failed to preserve the active conformation of the peptide epitope since it led to lower antibody binding compared to linear and dimeric peptides. The CD analysis showed that the tetrameric MAP constructs tend to adopt a beta-sheet structure due to intermolecular aggregation, which limits epitope accessibility. Our results demonstrate the value of biospecific interaction analysis technology using synthetic peptides for the diagnosis of acute hepatitis A.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11121543     DOI: 10.1016/s0022-1759(00)00295-7

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  5 in total

1.  A microarray biosensor for multiplexed detection of microbes using grating-coupled surface plasmon resonance imaging.

Authors:  Gregory Marusov; Andrew Sweatt; Kathryn Pietrosimone; David Benson; Steven J Geary; Lawrence K Silbart; Sreerupa Challa; Jacqueline Lagoy; David A Lawrence; Michael A Lynes
Journal:  Environ Sci Technol       Date:  2011-12-01       Impact factor: 9.028

2.  Transcription of the Rickettsia felis ompA gene in naturally infected fleas.

Authors:  Jorge E Zavala-Castro; Melissa Small; Colette Keng; Donald H Bouyer; Jorge Zavala-Velázquez; David H Walker
Journal:  Am J Trop Med Hyg       Date:  2005-10       Impact factor: 2.345

3.  Glycopeptide-based antibody detection in multiple sclerosis by surface plasmon resonance.

Authors:  Feliciana Real-Fernández; Irene Passalacqua; Elisa Peroni; Mario Chelli; Francesco Lolli; Anna Maria Papini; Paolo Rovero
Journal:  Sensors (Basel)       Date:  2012-05-02       Impact factor: 3.576

4.  Detection of Antibodies against Hepatitis A Virus (HAV) by a Surface Plasmon Resonance (SPR) Biosensor: A New Diagnosis Tool Based on the Major HAV Capsid Protein VP1 (SPR-HAVP1).

Authors:  Gabriel Menezes Costa Dos Santos; Carlos Roberto Alves; Marcelo Alves Pinto; Luciane Almeida Amado Leon; Franklin Souza-Silva
Journal:  Sensors (Basel)       Date:  2021-05-03       Impact factor: 3.576

5.  Multiple antigenic peptide (MAP): a synthetic peptide dendrimer for diagnostic, antiviral and vaccine strategies for emerging and re-emerging viral diseases.

Authors:  Vinay Ganeshrao Joshi; Vikas D Dighe; Dimpal Thakuria; Yashpal Singh Malik; Satish Kumar
Journal:  Indian J Virol       Date:  2013-09-06
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.