Literature DB >> 11117400

Recanalization of an occluded modified Blalock-Taussig shunt by balloon angioplasty within 12 hours of its construction.

M O Galal1, K Attas, G Baslaim.   

Abstract

An infant developed severe desaturation within a few hours of construction of a modified Blalock-Taussig shunt. Echocardiography revealed that the shunt had become occluded, and this was confirmed angiographically. At catheterisation, therefore, we passed a 0.014" percutaneous transluminal coronary angioplasty wire through the occluded shunt into the right pulmonary artery and then dilated the shunt successfully using a 5 mm coronary angioplasty balloon. Six weeks later, the shunt remained patent.

Entities:  

Mesh:

Year:  2000        PMID: 11117400     DOI: 10.1017/s1047951100008957

Source DB:  PubMed          Journal:  Cardiol Young        ISSN: 1047-9511            Impact factor:   1.093