Transthoracic three-dimensional echocardiography for the assessment of straddling tricuspid or mitral valves.

M Vogel1, S Y Ho, C Lincoln, R H Anderson.   

Abstract

BACKGROUND: The advent of 3D echocardiography has provided a technique which, potentially, could afford significant additional information over conventional cross-sectional echocardiography in the assessment of patients with straddling atrioventricular valves prior to surgical correction.
METHODS: Eight patients, aged from 1 month to 9.2 years, were examined with 3D echocardiography. All but three had discordant ventriculoarterial connections or double outlet right ventricle. Data suitable for reconstruction was acquired with transthoracic scanning. Right and left ventricular volumes were calculated in the 3D dataset.
RESULTS: 3D echocardiography proved capable of defining the exact degree of straddling by imaging the proportion of tension apparatus attached to either side of the ventricular septum. It was able also to display the atrioventricular junction "en face", thus permitting identification of the precise site of insertion of the muscular ventricular septum relative to the atrioventricular junction. This made it possible first, to calculate the degree of valvar override, and second, to predict the location of the penetrating atrioventricular bundle. End-diastolic volume of the right ventricle in those with straddling tricuspid valves was 73 (61-83)% of normal, and, of the left ventricle in those with mitral valvar straddling 71 (40-97)% of normal.
CONCLUSIONS: 3D echocardiography can aid in planning the optimal surgical procedure in patients with straddling or overrriding atrioventricular valves, as it provides diagnostic information superior to standard cross-sectional techniques. It also allows for exact measurement of the volumes of the respective ventricles.

Entities:  

Mesh:

Year:  2000        PMID: 11117393     DOI: 10.1017/s104795110000888x

Source DB:  PubMed          Journal:  Cardiol Young        ISSN: 1047-9511            Impact factor:   1.093


  3 in total

1.  Two-ventricle repair for complex congenital heart defects palliated towards single-ventricle repair.

Authors:  Brijesh P Kottayil; Gopalraj S Sunil; Mahesh Kappanayil; Sweta Harish Mohanty; Edwin Francis; Balu Vaidyanathan; Rakhi Balachandran; Suresh G Nair; Raman Krishna Kumar
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-12-05

Review 2.  Conversion of prior univentricular repairs to septated circulation: Case selection, challenges, and outcomes.

Authors:  Gopalraj S Sunil; Balaji Srimurugan; Brijesh P Kottayil; Praveen Reddy Bayya; Mahesh Kappanayil; Raman Krishna Kumar
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2020-07-01

3.  Real-time three-dimensional ultrasound - a valuable new tool in preoperative assessment of complex congenital cardiac disease.

Authors:  Pozza R Dalla; U Römer; R Kozlik-Feldmann; H Netz
Journal:  Images Paediatr Cardiol       Date:  2003-10