Literature DB >> 11110269

Nitric oxide added to the sweep gas infusion reduces local clotting formation in adult blood oxygenators.

H T Tevaearai1, X M Mueller, S Tepic, J Cotting, Y Boone, P M Montavon, L K von Segesser.   

Abstract

Nitric oxide (NO) is an inhibitor of platelet aggregation. We analyzed the effect of direct infusion of NO into adult blood oxygenators on local clot formation. Nonheparinized calves in a control group (n = 3) and NO group (n = 4) were connected to a jugulocarotid cardiopulmonary bypass (CPB; centrifugal pump) for 6 hours. The venous line and pumphead were heparin coated, whereas the oxygenator, the heat exchanger, and the arterial line were not. A total of 80 ppm of NO was mixed with the sweep gas infusion in the NO group. The pressure gradient through the oxygenator (delta<gd>P.Ox.) was monitored, and its evolution was compared between groups. Oxygenators membranes were analyzed and photographed, allowing for calculation of the percentage of surface area covered with clots by using a computer image analysis program. The delta<gd>P.Ox. reached a plateau of 193 +/- 26% of the basal value in the NO group after 120 minutes, whereas a similar plateau of 202 +/- 22% was reached after only 20 minutes in the control group (p < 0.05). The surface area of the oxygenator covered with clots was significantly reduced in the NO group (0.54 +/- 0.41%) compared with the control group (5.78 +/- 3.80%, p < 0.05). However, general coagulation parameters were not modified by local NO administration. The activated coagulation time remained stable between 110 and 150 seconds in both groups (p = not significant [ns]), and there were no differences in hematocrit, thrombin time, partial thromboplastin time, or fibrinogen between groups during the 6 hours of CPB. Thus, the mixed infusion of a continuous low dose of NO into adult oxygenators during prolonged CPB prevented local clot formation, whereas the general coagulation pattern remained unchanged.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11110269     DOI: 10.1097/00002480-200011000-00012

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  2 in total

1.  Establishment and evaluation of a rat model of extracorporeal membrane oxygenation (ECMO) thrombosis using a 3D-printed mock-oxygenator.

Authors:  Nao Umei; Angela Lai; Jennifer Miller; Suji Shin; Kalliope Roberts; Saif Ai Qatarneh; Shingo Ichiba; Atsuhiro Sakamoto; Keith E Cook
Journal:  J Transl Med       Date:  2021-04-28       Impact factor: 5.531

Review 2.  Advances in extracorporeal membrane oxygenator design for artificial placenta technology.

Authors:  David G Blauvelt; Emily N Abada; Peter Oishi; Shuvo Roy
Journal:  Artif Organs       Date:  2020-11-04       Impact factor: 3.094

  2 in total