Literature DB >> 11107200

A comparison of regional myocardial velocity information derived by pulsed and color Doppler techniques: an in vitro and in vivo study.

T Kukulski1, J U Voigt, U M Wilkenshoff, J M Strotmann, B Wranne, L Hatle, G R Sutherland.   

Abstract

The objective was to compare velocity information derived from either a tissue mimicking phantom or normal contracting myocardium by both pulsed wave and color Doppler myocardial imaging (PWDMI and CDMI). Both CDMI and PWDMI allow quantitative assessment of regional myocardial contraction and relaxation velocities, but their potential clinical applications have not yet been investigated. Moreover, no information is available as to whether they can be used interchangeably for regional velocity assessment. For the in vitro study, a rotating, circular-shaped, tissue-mimicking sponge driven by a motor at speeds of 15, 30, 60, 90 rpm was used to derive velocity data from the same eight points of interest by using PWDMI or CDMI techniques. For the in vivo study, 25 normal subjects were examined at rest using parasternal and apical approaches. Velocity profiles were derived from the same 26 areas of interest (18 left ventricular segments, 3 right ventricular segments, and 5 measurement points for the tricuspid and mitral annuli) for each technique. Peak maximal velocities were detected by PWDMI and peak mean velocities were measured using CDMI. The results of the in vitro study phantom showed excellent correlation (r = 0.99, P < 0. 001) and satisfactory agreement (0.04 cm/sec; 3.3 cm/sec) between both Doppler techniques. PWDMI velocities were higher than CDMI velocities by up to 20% and overestimated the real velocity value (0. 37 +/- 0.29 cm/sec) while CDMI underestimated predicted velocity by 1.35 +/- 0.36 cm/sec. Good correlation (r = 0.87, P < 0.001), but poor agreement (-2.1 cm/sec; 5.4 cm/sec) was shown in vivo for all segments with regard to peak systolic and diastolic velocities. Both Doppler techniques cannot be used interchangeably for comparing peak velocities in the clinical situation. However, with adequate temporal resolution, they can be used interchangeably for velocity profile recording and for timing of events.

Entities:  

Mesh:

Year:  2000        PMID: 11107200     DOI: 10.1046/j.1540-8175.2000.00639.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  8 in total

1.  Myocardial tissue motion influence on laser Doppler perfusion monitoring using tissue Doppler imaging.

Authors:  M G D Karlsson; L Hübbert; U Lönn; B Janerot-Sjöberg; H Casimir-Ahn; K Wårdell
Journal:  Med Biol Eng Comput       Date:  2004-11       Impact factor: 2.602

Review 2.  Diastolic dysfunction in diabetes and the metabolic syndrome: promising potential for diagnosis and prognosis.

Authors:  H von Bibra; M St John Sutton
Journal:  Diabetologia       Date:  2010-03-30       Impact factor: 10.122

3.  Colour tissue velocity imaging can show resynchronisation of longitudinal left ventricular contraction pattern by biventricular pacing in patients with severe heart failure.

Authors:  P Schuster; S Faerestrand; O-J Ohm
Journal:  Heart       Date:  2003-08       Impact factor: 5.994

4.  How similar are the mice to men? Between-species comparison of left ventricular mechanics using strain imaging.

Authors:  Kenya Kusunose; Marc S Penn; Youhua Zhang; Yuanna Cheng; James D Thomas; Thomas H Marwick; Zoran B Popović
Journal:  PLoS One       Date:  2012-06-29       Impact factor: 3.240

5.  Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible?

Authors:  Aristomenis Manouras; Arben Shala; Evangelia Nyktari; Kambiz Shahgaldi; Reidar Winter; Panagiotis Vardas; Lars-Ake Brodin; Jacek Nowak
Journal:  Cardiovasc Ultrasound       Date:  2009-06-23       Impact factor: 2.062

6.  Measurements of left ventricular myocardial longitudinal systolic displacement using spectral and colour tissue Doppler: time for a reassessment?

Authors:  Aristomenis Manouras; Kambiz Shahgaldi; Reidar Winter; Lars-Ake Brodin; Jacek Nowak
Journal:  Cardiovasc Ultrasound       Date:  2009-03-17       Impact factor: 2.062

7.  The predictive value of echocardiography for chronic thromboembolic pulmonary hypertension after acute pulmonary embolism in Korea.

Authors:  Jin Sup Park; Jinhee Ahn; Jung Hyun Choi; Hye Won Lee; Jun-Hyok Oh; Han Cheol Lee; Kwang Soo Cha; Taek Jong Hong
Journal:  Korean J Intern Med       Date:  2016-04-05       Impact factor: 2.884

8.  Overweight and obesity impair left ventricular systolic function as measured by left ventricular ejection fraction and global longitudinal strain.

Authors:  Peter Blomstrand; Peter Sjöblom; Mats Nilsson; Magnus Wijkman; Martin Engvall; Toste Länne; Fredrik H Nyström; Carl Johan Östgren; Jan Engvall
Journal:  Cardiovasc Diabetol       Date:  2018-08-14       Impact factor: 9.951

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.