Literature DB >> 11106989

Titanium for removable partial dentures (III): 2-year clinical follow-up in an undergraduate programme.

A R Au1, S K Lechner, C J Thomas, T Mori, P Chung.   

Abstract

This study examined the success of titanium (Ti) removable partial dentures (RPDs) compared with that of cobalt-chromium (Co-Cr) RPDs using a randomized controlled clinical trial. Thirty-eight RPD patients were provided with either Co-Cr (20 patients) or Ti (18 patients) RPDs. The total numbers of dentures was 31 (13 maxillary, 18 mandibular) for Co-Cr and 23 (11 maxillary, 12 mandibular) for Ti. Patients were reviewed for 24 months following denture issue. After the initial 12 months, 20 clinical problems were recorded and became the criteria for subsequent assessment. Incidence of failure was analysed using both Fisher's exact test and the chi square test at a significance level of P<0.05. Fracture of retainers in both metals occurred only in the first 12 months. Some failure types presented at significantly higher levels in the first 12 months but there were no significant differences between the two in all the criteria examined between the 12- and the 24-month reviews. Although differences existed in failure types between Co-Cr and Ti RPDs during the early review stages, the overall success rate of Ti RPDs was comparable with that of Co-Cr RPDs after 24 months. The higher incidence of failures in Ti RPDs prior to the 12-month review suggests the importance of taking its lower rigidity into account when designing RPDs.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11106989     DOI: 10.1046/j.1365-2842.2000.00576.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  6 in total

1.  The effect of disinfecting solutions on bending properties and weight changes of Co-Cr and Ti-6Al-7Nb alloys for dentures.

Authors:  Triantafillos Papadopoulos; Gregory Polyzois; Athena Tapanli; Maria Frangou
Journal:  Odontology       Date:  2011-01-27       Impact factor: 2.634

Review 2.  WITHDRAWN: Interventions for replacing missing teeth: partially absent dentition.

Authors:  Elliot Abt; Alan B Carr; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2019-07-17

3.  Biological complications of removable dental prostheses in the moderately reduced dentition: a systematic literature review.

Authors:  Ovidiu Moldovan; Heike Rudolph; Ralph G Luthardt
Journal:  Clin Oral Investig       Date:  2018-06-29       Impact factor: 3.573

Review 4.  Clinical performance of removable dental prostheses in the moderately reduced dentition: a systematic literature review.

Authors:  Ovidiu Moldovan; Heike Rudolph; Ralph G Luthardt
Journal:  Clin Oral Investig       Date:  2016-06-09       Impact factor: 3.573

Review 5.  Physico-mechanical properties and prosthodontic applications of Co-Cr dental alloys: a review of the literature.

Authors:  Youssef S Al Jabbari
Journal:  J Adv Prosthodont       Date:  2014-04-22       Impact factor: 1.904

Review 6.  Final-impression techniques and materials for making complete and removable partial dentures.

Authors:  Srinivasan Jayaraman; Balendra P Singh; Balasubramanian Ramanathan; Murukan Pazhaniappan Pillai; Laura MacDonald; Richard Kirubakaran
Journal:  Cochrane Database Syst Rev       Date:  2018-04-04
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.