Ultrasonographic detection of very thin percutaneous central venous catheter in neonates.

Y Ohki1, M Tabata, M Kuwashima, H Takeuchi, Y Nako, A Morikawa.   

Abstract

To assess the ability of ultrasonography to detect the tip of a very thin (0.4 mm outer diameter) percutaneous central venous catheter (PCVC) in neonates, the PCVC tip location was assessed by ultrasonography (US) and compared to the location estimated by standard radiography for 57 PCVCs in 44 neonates. Of 57 occasions, the examiner could not find the PCVC tip in three cases (5%). In the remaining 54 instances, in 87% of cases, the PCVC tip position was consistent with the location implied by skeletal landmarks on standard radiographs. On 24 occasions we also assessed catheter tip dislodgement according to flexion and extension of the infant's arm. US could detect 78% of cases of catheter tip dislodgement. The PCVC tip was sometimes visualized as a dot and parallel lines as well as mere parallel lines. In a large population of cases, US is a reliable method for detection of a thin PCVC tip. US provides precise information about the PCVC tip position in relation to vascular structure and contributes to safer positioning of the PCVC than traditional radiography alone.

Entities:  

Mesh:

Year:  2000        PMID: 11106054     DOI: 10.1080/080352500300002615

Source DB:  PubMed          Journal:  Acta Paediatr        ISSN: 0803-5253            Impact factor:   2.299


  5 in total

1.  Etamsylate for prevention of periventricular haemorrhage.

Authors:  R W Hunt
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2005-01       Impact factor: 5.747

2.  Use of hand-held ultrasonography to confirm the correct placement of a central venous catheter tip.

Authors:  Tomoyuki Ohta; Fumio Tsujimoto; Yasuo Nakajima; Akihiro Ohyama; Maho Sakamoto; Akiko Kishino; Kazumitsu Hamasuna; Giichiro Ohno; Atsushi Tsugu
Journal:  J Med Ultrason (2001)       Date:  2007-03-15       Impact factor: 1.314

3.  The superiority of point of care ultrasound in localizing central venous line tip position over time.

Authors:  Nahla Zaghloul; Laura Watkins; Jennie Choi-Rosen; Shahana Perveen; Dalibor Kurepa
Journal:  Eur J Pediatr       Date:  2018-10-29       Impact factor: 3.183

4.  Diagnostic accuracy of ultrasound for localising peripherally inserted central catheter tips in infants in the neonatal intensive care unit: a systematic review and meta-analysis.

Authors:  Shauna C Doyle; Niamh M Bergin; Rena Young; Andrew England; Mark F McEntee
Journal:  Pediatr Radiol       Date:  2022-05-05

5.  Echocardiographic Determination of Percutaneous Central Venous Catheters in the Superior Vena Cava: A Prospective Cohort Study.

Authors:  Yao-Sheng Wang; Hsin-Chun Huang; Yu-Chen Liu; I-Lun Chen
Journal:  Children (Basel)       Date:  2022-04-27
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.