Literature DB >> 11106009

Study on the lifetime and attenuation properties of microbubbles coated with carboxylic acid salts.

K Soetanto1, M Chan.   

Abstract

Four kinds of surfactants, sodium laurate, sodium myristate, sodium palmitate and sodium oleate were used to study the effects of surfactant coatings on the lifetime and attenuation of microbubbles. The changes in the size distribution of microbubbles prepared with these surfactants in saline were measured with a Coulter Multisizer (Coulter Electronics Ltd., Luton, UK). Frequency characteristics of ultrasonic attenuation of the microbubble suspensions were measured between 400 kHz and 6 MHz. From the changes in attenuation in the microbubble suspensions over time, it was found that the lifetime of microbubbles in a suspension also depends on the frequency of the irradiating ultrasound. The effect of surfactants on the frequency characteristics of attenuation was also studied, and characteristics of the surfactant coating, including shell elasticity and shell friction parameters were calculated from the measurement results. Microbubbles produced with sodium palmitate had the longest lifetime and the smallest average size. The shell had very little effect on the ultrasonic properties of microbubbles produced with sodium palmitate, suggesting that the sodium palmitate microbubbles behaved ultrasonically as free microbubbles.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11106009     DOI: 10.1016/s0041-624x(00)00027-5

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  4 in total

Review 1.  Ultrasonic drug delivery--a general review.

Authors:  William G Pitt; Ghaleb A Husseini; Bryant J Staples
Journal:  Expert Opin Drug Deliv       Date:  2004-11       Impact factor: 6.648

2.  Microbubbling by co-axial electrohydrodynamic atomization.

Authors:  U Farook; E Stride; M J Edirisinghe; R Moaleji
Journal:  Med Biol Eng Comput       Date:  2007-07-12       Impact factor: 2.602

3.  Preparation of suspensions of phospholipid-coated microbubbles by coaxial electrohydrodynamic atomization.

Authors:  U Farook; E Stride; M J Edirisinghe
Journal:  J R Soc Interface       Date:  2009-03-06       Impact factor: 4.118

4.  Effect of anesthesia carrier gas on in vivo circulation times of ultrasound microbubble contrast agents in rats.

Authors:  Lee Mullin; Ryan Gessner; James Kwan; Mehmet Kaya; Mark A Borden; Paul A Dayton
Journal:  Contrast Media Mol Imaging       Date:  2011-01-19       Impact factor: 3.161

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.