Literature DB >> 11105030

Contrast-enhanced breath-hold three-dimensional magnetic resonance angiography in the evaluation of renal arteries: optimization of technique and pitfalls.

A N Shetty1, K G Bis, M Kirsch, J Weintraub, G Laub.   

Abstract

The authors describe the optimization of a contrast-enhanced, breath-held, three-dimensional magnetic resonance angiography (CE-BH-3DMRA) technique in the assessment of the renal arteries and compare its utility with conventional x-ray angiography (XRA). Signal optimization using specific pulse sequence parameters was based on the patient's circulatory conditions, injection rate, and pulse sequence timing. Fifty-one patients (27 M, 24 F; mean age 69.7 years) were evaluated with CE-BH-3DMRA and XRA. All patients had an MR angiogram 3 months either before or after XRA. A test bolus study was performed for accurate assessment of transit time in each patient. A total of 51 patients (115 vessels) were studied in which the sensitivity and specificity for all renal artery stenoses including the proximal and mid-renal arterial segments were 96% and 92%, respectively. In-stent stenosis could only be diagnosed by quantifying flow beyond the stent using an additional triggered phase contrast cine pulse sequence. A total of 11 accessory renal arteries were correctly identified. In addition, fibromuscular dysplasia in two patients and stents in three patients were correctly identified on MRA. J. Magn. Reson. Imaging 2000;12:912-923. Copyright 2000 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2000        PMID: 11105030     DOI: 10.1002/1522-2586(200012)12:6<912::aid-jmri15>3.0.co;2-a

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  4 in total

Review 1.  Contemporary imaging techniques for the diagnosis of renal artery stenosis.

Authors:  T Leiner; M W de Haan; P J Nelemans; J M A van Engelshoven; G B C Vasbinder
Journal:  Eur Radiol       Date:  2005-06-28       Impact factor: 5.315

2.  Renal artery stenosis: comparative evaluation of gadolinium-enhanced MRA and DSA.

Authors:  F Stacul; S Gava; M Belgrano; S Cernic; L Pagnan; F Pozzi Mucelli; M A Cova
Journal:  Radiol Med       Date:  2008-05-15       Impact factor: 3.469

3.  Targeted Drug Delivery to Upper Airways Using a Pulsed Aerosol Bolus and Inhaled Volume Tracking Method.

Authors:  Yan Ostrovski; Simon Dorfman; Maksim Mezhericher; Stavros Kassinos; Josué Sznitman
Journal:  Flow Turbul Combust       Date:  2018-05-02       Impact factor: 2.305

4.  Ultrasound diagnostics of renal artery stenosis: Stenosis criteria, CEUS and recurrent in-stent stenosis.

Authors:  W Schäberle; L Leyerer; W Schierling; K Pfister
Journal:  Gefasschirurgie       Date:  2015-08-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.