Literature DB >> 11101613

Comparison of the Rodac imprint method to selective enrichment broth for recovery of vancomycin-resistant enterococci and drug-resistant Enterobacteriaceae from environmental surfaces.

D M Hacek1, W E Trick, S M Collins, G A Noskin, L R Peterson.   

Abstract

We compared the Rodac imprint technique to selective enrichment broth for detecting vancomycin-resistant enterococci (VRE) and multidrug-resistant Enterobacteriaceae (MDRE) on surfaces. Rodac plates contained tryptic soy agar with 5% sheep blood, vancomycin (6 microg/ml), ceftazidime (2 microg/ml), amphotericin B (2 microg/ml), and clindamycin (1 microg/ml). Two types of broth were used: brain heart infusion (BHI) and BHI plus vancomycin (6 microg/ml) and ceftazidime (2 microg/ml) (BHIVC). Of the 46 surfaces cultured for VRE, 12 (26%) were positive. Of the 12 VRE-positive surfaces, 11 (92%) grew from Rodac, 8 (67%) grew from BHIVC, and 7 (58%) grew from BHI. A larger study is needed for MDRE, as only 4 of 43 surfaces were MDRE positive. The Rodac imprint technique successfully recovered VRE from environmental surfaces.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11101613      PMCID: PMC87654     

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  10 in total

1.  Neomycin blood agar as a selective medium for vancomycin resistant Enterococcus faecium.

Authors:  M Ford; J D Perry; F K Gould; K E Orr
Journal:  J Clin Pathol       Date:  1996-05       Impact factor: 3.411

2.  Comparison of five selective media for identifying fecal carriage of vancomycin-resistant enterococci.

Authors:  D Landman; J M Quale; E Oydna; B Willey; V Ditore; M Zaman; K Patel; G Saurina; W Huang
Journal:  J Clin Microbiol       Date:  1996-03       Impact factor: 5.948

3.  Comparison of direct plating and broth enrichment culture for the detection of intestinal colonization by glycopeptide-resistant enterococci among hospitalized patients.

Authors:  M Ieven; E Vercauteren; P Descheemaeker; F van Laer; H Goossens
Journal:  J Clin Microbiol       Date:  1999-05       Impact factor: 5.948

4.  Hospital-acquired infection with vancomycin-resistant Enterococcus faecium transmitted by electronic thermometers.

Authors:  L L Livornese; S Dias; C Samel; B Romanowski; S Taylor; P May; P Pitsakis; G Woods; D Kaye; M E Levison
Journal:  Ann Intern Med       Date:  1992-07-15       Impact factor: 25.391

5.  Environmental study of a methicillin-resistant Staphylococcus aureus epidemic in a burn unit.

Authors:  W A Rutala; E B Katz; R J Sherertz; F A Sarubbi
Journal:  J Clin Microbiol       Date:  1983-09       Impact factor: 5.948

6.  Comparison of methods for recovery of Clostridium difficile from an environmental surface.

Authors:  B P Buggy; K H Wilson; R Fekety
Journal:  J Clin Microbiol       Date:  1983-08       Impact factor: 5.948

7.  Evaluation of cycloserine-cefoxitin-fructose agar and cycloserine-cefoxitin-fructose broth for recovery of Clostridium difficile from environmental sites.

Authors:  C R Clabots; K M Bettin; L R Peterson; D N Gerding
Journal:  J Clin Microbiol       Date:  1991-11       Impact factor: 5.948

8.  Recovery of vancomycin-resistant enterococci on fingertips and environmental surfaces.

Authors:  G A Noskin; V Stosor; I Cooper; L R Peterson
Journal:  Infect Control Hosp Epidemiol       Date:  1995-10       Impact factor: 3.254

9.  Hospital carpeting and epidemiology of Clostridium difficile.

Authors:  A T Skoutelis; G O Westenfelder; M Beckerdite; J P Phair
Journal:  Am J Infect Control       Date:  1994-08       Impact factor: 2.918

10.  Recommendations for preventing the spread of vancomycin resistance. Recommendations of the Hospital Infection Control Practices Advisory Committee (HICPAC).

Authors: 
Journal:  MMWR Recomm Rep       Date:  1995-09-22
  10 in total
  5 in total

1.  Contamination of the clinical microbiology laboratory with vancomycin-resistant enterococci and multidrug- resistant Enterobacteriaceae: implications for hospital and laboratory workers.

Authors:  S M Collins; D M Hacek; L A Degen; M O Wright; G A Noskin; L R Peterson
Journal:  J Clin Microbiol       Date:  2001-10       Impact factor: 5.948

2.  Detection of methicillin-resistant Staphylococcus aureus and vancomycin-resistant enterococci on the gowns and gloves of healthcare workers.

Authors:  Graham M Snyder; Kerri A Thom; Jon P Furuno; Eli N Perencevich; Mary-Claire Roghmann; Sandra M Strauss; Giora Netzer; Anthony D Harris
Journal:  Infect Control Hosp Epidemiol       Date:  2008-07       Impact factor: 3.254

3.  Study of the Effectiveness of Multipurpose Solutions on the Bacterial Disinfection of Silicone Hydrogel Contact Lenses In Vitro.

Authors:  Priscila C Correa; Aline C F Lui; Cely B Silva; Carolina P B Gracitelli; Lycia M Mimica; Suzethe M Sasagawa; Adamo L Netto
Journal:  Eye Contact Lens       Date:  2018-11       Impact factor: 2.018

4.  Factors influencing environmental sampling recovery of healthcare pathogens from non-porous surfaces with cellulose sponges.

Authors:  Laura J Rose; Hollis Houston; Marla Martinez-Smith; Amanda K Lyons; Carrie Whitworth; Sujan C Reddy; Judith Noble-Wang
Journal:  PLoS One       Date:  2022-01-13       Impact factor: 3.240

5.  Bacterial contamination of healthcare workers' uniforms: a randomized controlled trial of antimicrobial scrubs.

Authors:  Marisha Burden; Angela Keniston; Maria G Frank; Carrie A Brown; Jeff Zoucha; Lilia Cervantes; Diane Weed; Kathy Boyle; Connie Price; Richard K Albert
Journal:  J Hosp Med       Date:  2013-06-12       Impact factor: 2.960

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.