Dosimetric characteristics of a new 125I brachytherapy source.

D M Gearheart1, A Drogin, K Sowards, A S Meigooni, G S Ibbott.   

Abstract

125I brachytherapy sources are being used for interstitial implants in tumor sites such as the prostate. Recently, a new 125I source has been introduced, which has a design different from that of other sources presently on the market. Dosimetric characteristics of this source, including dose rate constant, radial dose function, and anisotropy function, were determined experimentally following the AAPM Task Group 43 recommendations. The characteristics were related to the 1999 NIST calibration assigned to this source [SK,99std]. Measurements were performed in a solid water phantom using LiF thermoluminescent dosimeters. For these measurements, slabs of solid water phantom material were machined to accommodate the source and LiF TLD chips of dimensions (3.1 x 3.1 x 0.8 mm3) and (1.0 x 1.0 x 1.0 mm3). The TLD chips were surrounded by at least 10 cm of solid water phantom material to provide full scattering conditions. The results indicated a dose rate constant, lambda, of 0.88 +/- 0.07cGyh(-1)U(-1) for the new 1251 source as compared to 0.98 and 1.04 cGy h(-1)U(-1) for the Nycomed/Amersham model 6711 and 6702 seeds, respectively. Per TG-43, the values reported here represent the dose absorbed by water at 1 cm from the source in a water medium. The radial dose function, g(r), of the new 125I source was measured at distances ranging from 0.5 to 10 cm. The anisotropy function, F(r,theta), of the new 125I source was measured at distances of 2 and 5 cm from the source center. Calculations of anisotropy and radial dose function were also made using a Monte Carlo code. These calculations were made for both solid water and liquid water, the former to validate the Monte Carlo code and the latter to provide results in liquid water for clinical use. All data compared favorably with those from the Nycomed/Amersham models 6711 and 6702 sources.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11099194     DOI: 10.1118/1.1290486

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  The dosimetric feasibility of gold nanoparticle-aided radiation therapy (GNRT) via brachytherapy using low-energy gamma-/x-ray sources.

Authors:  Sang Hyun Cho; Bernard L Jones; Sunil Krishnan
Journal:  Phys Med Biol       Date:  2009-07-27       Impact factor: 3.609

2.  Monte Carlo simulations and radiation dosimetry measurements of peripherally applied HDR 192Ir breast brachytherapy D-shaped applicators.

Authors:  Yun Yang; Mark J Rivard
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

3.  Impact of the vaginal applicator and dummy pellets on the dosimetry parameters of Cs-137 brachytherapy source.

Authors:  Sedigheh Sina; Reza Faghihi; Ali S Meigooni; Simin Mehdizadeh; M Amin Mosleh Shirazi; Mehdi Zehtabian
Journal:  J Appl Clin Med Phys       Date:  2011-05-19       Impact factor: 2.243

4.  Monte Carlo calculations and experimental measurements of the TG-43U1-recommended dosimetric parameters of 125I (Model IR-Seed2) brachytherapy source.

Authors:  Sahar Sheikholeslami; Hasan Ali Nedaie; Mahdi Sadeghi; Hosein Pourbeigy; Sohrab Shahzadi; Mehdi Zehtabian; Mohsen Hasani; Ali S Meigooni
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.