Verification of lung dose in an anthropomorphic phantom calculated by the collapsed cone convolution method.

M J Butson1, R Elferink, T Cheung, P K Yu, M Stokes, K Y Quach, P Metcalfe.   

Abstract

Verification of calculated lung dose in an anthropomorphic phantom is performed using two dosimetry media. Dosimetry is complicated by factors such as variations in density at slice interfaces and appropriate position on CT scanning slice to accommodate these factors. Dose in lung for a 6 MV and 10 MV anterior-posterior field was calculated with a collapsed cone convolution method using an ADAC Pinnacle, 3D planning system. Up to 5% variations between doses calculated at the centre and near the edge of the 2 cm phantom slice positioned at the beam central axis were seen, due to the composition of each phantom slice. Validation of dose was performed with LiF thermoluminescent dosimeters (TLDs) and X-Omat V radiographic film. Both dosimetry media produced dose results which agreed closely with calculated results nearest their physical positioning in the phantom. The collapsed cone convolution method accurately calculates dose within inhomogeneous lung regions at 6 MV and 10 MV x-ray energy.

Entities:  

Mesh:

Year:  2000        PMID: 11098921     DOI: 10.1088/0031-9155/45/11/402

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Algorithms used in heterogeneous dose calculations show systematic differences as measured with the Radiological Physics Center's anthropomorphic thorax phantom used for RTOG credentialing.

Authors:  Stephen F Kry; Paola Alvarez; Andrea Molineu; Carrie Amador; James Galvin; David S Followill
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-01-01       Impact factor: 7.038

2.  Optimization of extracranial stereotactic radiation therapy of small lung lesions using accurate dose calculation algorithms.

Authors:  Barbara Dobler; Cornelia Walter; Antje Knopf; Daniella Fabri; Rainer Loeschel; Martin Polednik; Frank Schneider; Frederik Wenz; Frank Lohr
Journal:  Radiat Oncol       Date:  2006-11-29       Impact factor: 3.481

3.  Dosimetry of oblique tangential photon beams calculated by superposition/convolution algorithms: a Monte Carlo evaluation.

Authors:  James C L Chow; Runqing Jiang; Michael K K Leung
Journal:  J Appl Clin Med Phys       Date:  2010-11-03       Impact factor: 2.102

4.  Parallel/Opposed: IMRT QA using treatment log files is superior to conventional measurement-based method.

Authors:  Nathan Childress; Quan Chen; Yi Rong
Journal:  J Appl Clin Med Phys       Date:  2015-01-08       Impact factor: 2.102

5.  Pinnacle3 modeling and end-to-end dosimetric testing of a Versa HD linear accelerator with the Agility head and flattening filter-free modes.

Authors:  Daniel L Saenz; Ganesh Narayanasamy; Wilbert Cruz; Nikos Papanikolaou; Sotirios Stathakis
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

6.  Evaluation of the Lung Dose in Three-dimensional Conformal Radiation Therapy of Left-Sided Breast Cancer: A Phantom Study.

Authors:  Mahsa Abdemanafi; Mohammad Bagher Tavakoli; Ali Akhavan; Iraj Abedi
Journal:  J Med Signals Sens       Date:  2020-02-06

7.  Evaluation of the analytical anisotropic algorithm in an extreme water-lung interface phantom using Monte Carlo dose calculations.

Authors:  Isabelle M Gagné; Sergei Zavgorodni
Journal:  J Appl Clin Med Phys       Date:  2006-06-16       Impact factor: 2.102

8.  Dosimetric comparison of extended dose range film with ionization measurements in water and lung equivalent heterogeneous media exposed to megavoltage photons.

Authors:  Paule M Charland; Indrin J Chetty; Shigeru Yokoyama; Benedick A Fraass
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.