Dual-window scatter correction and energy window setting in cerebral blood flow SPECT: a Monte Carlo study.

A Gustafsson1, A Arlig, L Jacobsson, M Ljungberg, C Wikkelsö.   

Abstract

The image quality in SPECT studies of the regional cerebral blood flow (rCBF) performed with 99mTc-HMPAO is degraded by scattered photons. The finite energy resolution of the gamma camera makes the detection of scattered photons unavoidable, and this is observed in the image as an impaired contrast between grey and white matter structures. In this work, a Monte Carlo simulated SPECT study of a realistic voxel-based brain phantom was used to evaluate the resulting contrast-to-noise ratio for a number of energy window settings, with and without the dual-window scatter correction. Values of the scaling factor k, used to obtain the fraction of scattered photons in the photopeak window, were estimated for each energy window. The use of a narrower, asymmetric, energy discrimination window improved the contrast, with a subsequent increase in statistical noise due to the lower number of counts. The photopeak-window setting giving the best contrast-to-noise ratio was found to be the same whether or not scatter correction was applied. Its value was 17% centred at 142 keV. At the optimum photopeak-window setting, the contrast was improved by using scatter correction, but the contrast-to-noise ratio was made worse.

Mesh:

Substances:

Year:  2000        PMID: 11098915     DOI: 10.1088/0031-9155/45/11/323

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Evaluation of quantitative accuracy among different scatter corrections for quantitative bone SPECT/CT imaging.

Authors:  Kenta Miwa; Reo Nemoto; Hirotsugu Masuko; Tensho Yamao; Rinya Kobayashi; Noriaki Miyaji; Kosuke Inoue; Hiroya Onodera
Journal:  PLoS One       Date:  2022-06-06       Impact factor: 3.752

2.  Optimisation of quantitative lung SPECT applied to mild COPD: a software phantom simulation study.

Authors:  Pernilla Norberg; Anna Olsson; Gudrun Alm Carlsson; Michael Sandborg; Agnetha Gustafsson
Journal:  EJNMMI Res       Date:  2015-03-22       Impact factor: 3.138

3.  Improving quantitative dosimetry in (177)Lu-DOTATATE SPECT by energy window-based scatter corrections.

Authors:  Robin de Nijs; Vera Lagerburg; Thomas L Klausen; Søren Holm
Journal:  Nucl Med Commun       Date:  2014-05       Impact factor: 1.690

4.  A New Approach for Scatter Removal and Attenuation Compensation from SPECT/CT Images.

Authors:  Shabnam Oloomi; Hadi Noori Eskandari; Seyed Rasoul Zakavi; Peter Knoll; Faraz Kalantari; Mohsen Hajizadeh Saffar
Journal:  Iran J Basic Med Sci       Date:  2013-11       Impact factor: 2.699

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.