Correlation between high-resolution computed tomographic, magnetic resonance and pathological findings in cases with non-cancerous but suspicious lung nodules.

F Li1, S Sone, Y Maruyama, S Takashima, Z G Yang, M Hasegawa, T Honda, T Yamanda, K Kubo.   

Abstract

Computed tomography scans, including thin-section high-resolution computed tomography (HRCT), occasionally fail to differentiate between small non-cancerous nodules from lung cancers. We describe nine such lesions ( < 20 mm in diameter) initially identified through our screening program for lung cancer using CT scanning. Pathological diagnoses included nodular fibrosis (n = 4), granuloma (n = 1), cryptococcoma (n = 1), localised organising pneumonia (n = 1), inflammatory pseudo-tumour (n = 1) and sclerosing haemangioma (n = 1). High-resolution CT findings, together with MRI findings with contrast-enhanced dynamic studies, were retrospectively evaluated. Additional cases should be identified and radiologically characterised in order to reduce the number of non-cancerous tumours that are treated by unnecessary surgery.

Entities:  

Mesh:

Year:  2000        PMID: 11097406     DOI: 10.1007/s003300000426

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  4 in total

1.  Detection of small pulmonary nodules in high-field MR at 3 T: evaluation of different pulse sequences using porcine lung explants.

Authors:  M Regier; S Kandel; M G Kaul; B Hoffmann; H Ittrich; P M Bansmann; J Kemper; C Nolte-Ernsting; M Heller; G Adam; J Biederer
Journal:  Eur Radiol       Date:  2006-09-30       Impact factor: 5.315

Review 2.  Perspectives for preventive screening with total body MRI.

Authors:  Susanne C Ladd; Mark E Ladd
Journal:  Eur Radiol       Date:  2007-06-05       Impact factor: 5.315

3.  Radiological Image Traits Predictive of Cancer Status in Pulmonary Nodules.

Authors:  Ying Liu; Yoganand Balagurunathan; Thomas Atwater; Sanja Antic; Qian Li; Ronald C Walker; Gary T Smith; Pierre P Massion; Matthew B Schabath; Robert J Gillies
Journal:  Clin Cancer Res       Date:  2016-09-23       Impact factor: 12.531

4.  Focal interstitial fibrosis manifesting as nodular ground-glass opacity: thin-section CT findings.

Authors:  Chang Min Park; Jin Mo Goo; Hyun Ju Lee; Chang Hyun Lee; Doo Hyun Chung; Eun Ju Chun; Jung-Gi Im
Journal:  Eur Radiol       Date:  2007-02-14       Impact factor: 5.315