Literature DB >> 11096037

Access recirculation in temporary hemodialysis catheters as measured by the saline dilution technique.

M A Little1, P J Conlon, J J Walshe.   

Abstract

Ultrasound dilution technology is emerging as the standard for measuring access recirculation and blood flow in hemodialysis patients. In temporary dialysis catheters, studies using the traditional two-needle urea method have suggested that short femoral catheters are associated with an unacceptably high degree of recirculation. This problem has never been assessed using ultrasound dilution technology. We performed a prospective observational study of consecutive patients undergoing dialysis through a temporary catheter. Measurements were made on 49 catheters; 10 catheters were excluded because poor flow necessitated reversal of the dialysis ports. Thirty-nine catheters in 33 patients were included in this analysis, of which 26 catheters were located in the femoral vein, and 13 catheters, in the internal jugular vein. Dialyzer blood flow was adjusted to give an ultrasonic flow rate of 250 mL/min (actual mean blood flow, 234.3 mL/min; 95% confidence interval [CI], 228 to 241). Overall mean recirculation rate was 8.9% (95% CI, 4.8 to 13.0). Multivariate analysis showed catheter location and length to be independent predictors of recirculation. Blood flow (within the range tested), duration into dialysis, time since catheter insertion, cardiac rhythm, and catheter type had no significant effect on recirculation rates. Recirculation in femoral catheters (13.1%) was significantly greater than that in internal jugular catheters (0.4%; P: < 0.001). Femoral catheters shorter than 20 cm had significantly greater recirculation (26.3%) than those longer than 20 cm (8.3%; P: = 0.007). We conclude that temporary femoral catheters shorter than 20 cm are associated with increased recirculation rates. In addition, when dialysis dose delivery is a priority, locating the temporary catheter in the internal jugular vein is an advantage.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11096037     DOI: 10.1053/ajkd.2000.19821

Source DB:  PubMed          Journal:  Am J Kidney Dis        ISSN: 0272-6386            Impact factor:   8.860


  8 in total

1.  Vascular access sites for acute renal replacement in intensive care units.

Authors:  Audrey E Dugué; Stéphanie P Levesque; Marc-Olivier Fischer; Bertrand Souweine; Jean-Paul Mira; Bruno Megarbane; Cédric Daubin; Damien du Cheyron; Jean-Jacques Parienti
Journal:  Clin J Am Soc Nephrol       Date:  2011-11-10       Impact factor: 8.237

2.  Section 5: Dialysis Interventions for Treatment of AKI.

Authors: 
Journal:  Kidney Int Suppl (2011)       Date:  2012-03

3.  Renal replacement therapy in adult and pediatric intensive care : Recommendations by an expert panel from the French Intensive Care Society (SRLF) with the French Society of Anesthesia Intensive Care (SFAR) French Group for Pediatric Intensive Care Emergencies (GFRUP) the French Dialysis Society (SFD).

Authors:  Christophe Vinsonneau; Emma Allain-Launay; Clarisse Blayau; Michael Darmon; Damien Ducheyron; Theophile Gaillot; Patrick M Honore; Etienne Javouhey; Thierry Krummel; Annie Lahoche; Serge Letacon; Matthieu Legrand; Mehran Monchi; Christophe Ridel; René Robert; Frederique Schortgen; Bertrand Souweine; Patrick Vaillant; Lionel Velly; David Osman; Ly Van Vong
Journal:  Ann Intensive Care       Date:  2015-12-30       Impact factor: 6.925

4.  Vascular Access Site for Renal Replacement Therapy in Acute Kidney Injury: A Post hoc Analysis of the ATN Study.

Authors:  Yue-Harn Ng; Kavitha Ganta; Herbert Davis; V Shane Pankratz; Mark Unruh
Journal:  Front Med (Lausanne)       Date:  2017-04-11

5.  Catheter Port Reversal in Citrate Continuous Veno-Venous Hemofiltration.

Authors:  Willem Boer; Mathias Van Tornout; Margot Vander Laenen; Kim Engelen; Ingrid Meex; Philippe Jorens
Journal:  Kidney Int Rep       Date:  2021-08-13

6.  How to deal with dialysis catheters in the ICU setting.

Authors:  Natacha Mrozek; Alexandre Lautrette; Jean-François Timsit; Bertrand Souweine
Journal:  Ann Intensive Care       Date:  2012-11-23       Impact factor: 6.925

Review 7.  Contrast-induced acute kidney injury and renal support for acute kidney injury: a KDIGO summary (Part 2).

Authors:  Norbert Lameire; John A Kellum
Journal:  Crit Care       Date:  2013-02-04       Impact factor: 9.097

8.  Cannula Design and Recirculation During Venovenous Extracorporeal Membrane Oxygenation.

Authors:  Oscar Palmér; Kenneth Palmér; Jan Hultman; Mikael Broman
Journal:  ASAIO J       Date:  2016 Nov/Dec       Impact factor: 2.872

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.