A new dual activation simulator of the left heart that reproduces physiological and pathological conditions.

F Mouret1, V Garitey, T Gandelheid, J Fuseri, R Rieu.   

Abstract

Heart valve replacements are often associated with cardiac pathologies, but valvular prostheses are still tested in vitro under the same physiological conditions as for a healthy young man. Therefore a new mock circulatory system of the left heart, the dual activation simulator (DAS), has been built. The DAS allows atrial and ventricular dynamics to be controlled with pumps that activate anatomically shaped silicon models of the cavities. The mitral flow is a two-peak waveform. The E/A ratio can be changed, and the A-wave can be suppressed to simulate, for instance, atrial fibrillation. The cardiac rhythm and the mean flow-rate can be changed at will. The ability of the DAS to reproduce physiological flow is assessed by computation of the aortic input impedance and by harmonic analysis of left ventricular and atrial pressures. It allows the behaviour of valve prostheses to be studied in various conditions of concern to clinicians and can be a useful tool for engineers to improve valve prostheses or validate diagnostic tools such as 3D colour Doppler. The DAS and its capacities are described.

Entities:  

Mesh:

Year:  2000        PMID: 11094814     DOI: 10.1007/BF02345753

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  12 in total

1.  Test procedure for artificial mitral valves.

Authors:  K Schichl; K Affeld; S Dreysse
Journal:  Int J Artif Organs       Date:  1998-01       Impact factor: 1.595

2.  Directions for improvement of substitute heart valves: National Heart, Lung, and Blood Institute's Working Group report on heart valves.

Authors:  L H Edmunds; S Mckinlay; J M Anderson; T H Callahan; J H Chesebro; E A Geiser; D M Makanani; L V McIntire; W Q Meeker; G K Naughton; J A Panza; F J Schoen; P Didisheim
Journal:  J Biomed Mater Res       Date:  1997

3.  Nonsymmetric leaflet motion of St. Jude Medical mitral valves simulated with a computer-controlled hydraulic mock circulator.

Authors:  Y Ohta; K Okamoto; M Sonderegger; T Dohi; H Matsumoto; T Horiuchi
Journal:  Artif Organs       Date:  1997-04       Impact factor: 3.094

4.  "Diastology": beyond E and A.

Authors:  R A Nishimura; C P Appleton
Journal:  J Am Coll Cardiol       Date:  1996-02       Impact factor: 24.094

5.  An aortic--left ventricular pulse duplicator used in testing prosthetic aortic heart valves.

Authors:  J F Cornhill
Journal:  J Thorac Cardiovasc Surg       Date:  1977-04       Impact factor: 5.209

6.  Simulation of blood flow by a hydrodynamic generator.

Authors:  P Issartier; M Siouffi; R Pelissier
Journal:  Med Prog Technol       Date:  1978-11-13

7.  Atrial fibrillation after cardiac surgery: a major morbid event?

Authors:  G H Almassi; T Schowalter; A C Nicolosi; A Aggarwal; T E Moritz; W G Henderson; R Tarazi; A L Shroyer; G K Sethi; F L Grover; K E Hammermeister
Journal:  Ann Surg       Date:  1997-10       Impact factor: 12.969

8.  Left atrial spontaneous echo contrast in asymptomatic patients with a mechanical valve prosthesis.

Authors:  T M Lee; N K Chou; S F Su; Y J Lin; M F Chen; C S Liau; Y T Lee; S H Chu
Journal:  Ann Thorac Surg       Date:  1996-12       Impact factor: 4.330

9.  Vascular load defined by the aortic input impedance spectrum.

Authors:  W W Nichols; C J Pepine; E A Geiser; C R Conti
Journal:  Fed Proc       Date:  1980-02

10.  Input impedance of the systemic circulation in man.

Authors:  W W Nichols; C R Conti; W E Walker; W R Milnor
Journal:  Circ Res       Date:  1977-05       Impact factor: 17.367

View more
  1 in total

1.  Hybrid Mock Circulatory Loop Simulation of Extreme Cardiac Events.

Authors:  Ethan S Rapp; Suraj R Pawar; Raul G Longoria
Journal:  IEEE Trans Biomed Eng       Date:  2022-08-19       Impact factor: 4.756

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.