The McCoy laryngoscope, external laryngeal pressure, and their combined use.

T Harioka1, K Nomura, K Mukaida, S Hosoi, S Nakao.   

Abstract

The efficacy of the McCoy laryngoscope, external laryngeal pressure, and their combination to improve the laryngoscopic view was evaluated in 219 patients and compared with the Macintosh laryngoscope. An experienced laryngoscopist performed laryngoscopy twice using the Macintosh laryngoscope and the McCoy laryngoscope in a random sequence, and external laryngeal pressure was applied in each laryngoscopy with the laryngoscopist's right hand. The laryngoscopic view obtained was graded on our modified Cormack's method. Without external laryngeal pressure, the McCoy laryngoscope provided a better laryngoscopic view than that obtained by the Macintosh laryngoscope (P < 0.001, signed rank test), but the view was worse than that with the Macintosh laryngoscope under external laryngeal pressure (P < 0.001). The McCoy laryngoscope combined with external laryngeal pressure provided a better view than the Macintosh laryngoscope with external laryngeal pressure (P < 0.001).

Entities:  

Mesh:

Year:  2000        PMID: 11094670     DOI: 10.1177/0310057X0002800509

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  1 in total

1.  Optimal external laryngeal manipulation versus McCoy blade in active position in patients with poor view of glottis on direct laryngoscopy.

Authors:  Arumugam Vasudevan; Ranjani Venkat; Ashok Shankar Badhe
Journal:  Indian J Anaesth       Date:  2010-01