Literature DB >> 11093651

Comparison of different sorbent materials for on-line solid-phase extraction with liquid chromatography-atmospheric pressure chemical ionization mass spectrometry of phenols.

R Wissiack1, E Rosenberg, M Grasserbauer.   

Abstract

On-line solid-phase extraction (SPE) was interfaced to liquid chromatography with atmospheric pressure chemical ionization mass spectrometry (HPLC-APCI-MS) for the determination of US Environmental Protection Agency (EPA) phenols. The system, allowing fully automated operation, was used to evaluate different SPE cartridge materials and dimensions. Six different SPE materials (C18 HD, Polymer Labs PLRP-s, Hamilton PRP-1, Hysphere GP, Hysphere SH and Waters Oasis) were tested. Criteria for their comparison were first the recovery for the different phenols and its reproducibility, but also chromatographically relevant items like peakshape in the on-line elution mode. High recoveries and good relative standard deviations were obtained particularly for the newer, strongly retaining SPE materials that have become commercially available recently (the Hysphere materials and Waters Oasis) compared to the well known silica-based and weaker polymeric adsorbents like PLRP-s and PRP-1. These advantages are, however, traded in for good chromatographic peakshape, since the stronger adsorbents give rise to notable peak broadening in on-line elution. This is particularly true when using APCI-MS detection which on the one hand offers excellent selectivity and sensitivity, but imposes additional restrictions on the mobile phase composition in order not to suppress the response significantly. The influence of these parameters on the on-line-SPE-HPLC-MS determination of EPA phenols is discussed and present limitations are pointed out.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11093651     DOI: 10.1016/s0021-9673(00)00730-5

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  Evaluation of resin and fatty acid concentration levels by online sample enrichment followed by atmospheric pressure chemical ionization-mass spectrometry (APCI-MS).

Authors:  Piia Valto; Juha Knuutinen; Raimo Alén
Journal:  Environ Sci Pollut Res Int       Date:  2008-10-14       Impact factor: 4.223

Review 2.  Methodologies for the extraction of phenolic compounds from environmental samples: new approaches.

Authors:  Cristina Mahugo Santana; Zoraida Sosa Ferrera; M Esther Torres Padrón; José Juan Santana Rodríguez
Journal:  Molecules       Date:  2009-01-09       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.