Literature DB >> 11093636

Off-line size-exclusion chromatographic fractionation-matrix-assisted laser desorption ionization time-of-flight mass spectrometry for polymer characterization. Theoretical and experimental study.

X Lou1, J L van Dongen, E W Meijer.   

Abstract

The parameters affecting the fractionation performance in size-exclusion chromatography (SEC) of broad polymer samples were investigated. Some equations were derived which enable the prediction of polydispersity (PD) in an SEC fraction. Good agreements were obtained between the calculated data and the experimental values. Based on these equations, SEC fractionation conditions were optimized. In the off-line SEC-matrix-assisted laser desorption ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS), two different modes can be employed, i.e., using MALDI-MS to provide an absolute calibration curve for SEC, or using SEC as a sample preparation step for MALDI-MS measurements. It was demonstrated that it is more reliable to use the latter combination, because most problems inherent in SEC can be circumvented. Some guidelines for the optimization of off-line SEC fractionation-MALDI-TOF-MS were given. It was found that under optimized conditions normally only a few SEC fractions are already sufficient to separate a highly polydisperse sample into portions of low PD that can accurately be measured by MALDI-TOF-MS.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11093636     DOI: 10.1016/s0021-9673(00)00417-9

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Comparative studies of poly(dimethyl siloxanes) using automated GPC-MALDI-TOF MS and on-line GPC-ESI-TOF MS.

Authors:  X Michael Liu; E Peter Maziarz; David J Heiler; George L Grobe
Journal:  J Am Soc Mass Spectrom       Date:  2003-03       Impact factor: 3.109

2.  Correlations between Chemical Compositions and Retention Times of Methacrylate Random Copolymers Using LC-ESI-MS.

Authors:  Hirotaka Hisatomi; Yukari Nishimoto; Hideya Kawasaki; Hikaru Momose; Koichi Ute; Ryuichi Arakawa
Journal:  Mass Spectrom (Tokyo)       Date:  2012-11-16

3.  MALDI SpiralTOF high-resolution mass spectrometry and Kendrick mass defect analysis applied to the characterization of poly(ethylene-co-vinyl acetate) copolymers.

Authors:  Thierry Fouquet; Sayaka Nakamura; Hiroaki Sato
Journal:  Rapid Commun Mass Spectrom       Date:  2016-04-15       Impact factor: 2.419

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.