Literature DB >> 11093490

Off-pump coronary bypass operations significantly reduce S100 release: an indicator for less cerebral damage?

W Wandschneider1, M Thalmann, E Trampitsch, G Ziervogel, G Kobinia.   

Abstract

BACKGROUND: Cardiac operations using extracorporeal circulation bear a risk of cerebral complications. The aim of our study was to investigate if off-pump operations without heart-lung machines can reduce cerebral injury.
METHODS: S100, a protein specific for cerebral tissue, was used as a marker for cerebral impairment in 108 randomized patients undergoing coronary bypass operation: 67 patients (group A) were operated on with extracorporeal circulation and cardioplegic cardiac arrest, and 41 patients (group B) underwent off-pump beating heart revascularization. Both groups were similar regarding age, sex, ejection fraction, and number of anastomoses. S100 levels were measured from induction of anesthesia until 24 hours after the operation.
RESULTS: Data collection was 100% complete. There was no in-hospital death. Nonfatal myocardial infarctions occurred in 2 patients in group A, and 1 patient in group B required resternotomy for bleeding. There was no neurologic deficit in either group. S100 levels increased only slightly in the off-pump patients (group B), whereas in group A there was a sharp rise in S100 concentration during extracorporeal circulation, only returning to baseline 6 hours after the end of the operation. Peak S100 levels were four times higher in group A than in group B (2.1 microg/L versus 0.5 microg/L; p < 001).
CONCLUSIONS: The results of our study suggest that perioperative cerebral impairment is reduced in cardiac operations without the use of extracorporeal circulation. Further large-scale studies are needed to show whether this result is reflected by fewer neurologic deficits.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11093490     DOI: 10.1016/s0003-4975(00)01843-9

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  7 in total

Review 1.  Pump or no pump for coronary artery bypass: current best available evidence.

Authors:  Shahzad G Raja
Journal:  Tex Heart Inst J       Date:  2005

Review 2.  A systematic review of the quality of publications reporting coronary artery bypass grafting trials.

Authors:  Forough Farrokhyar; Rong Chu; Richard Whitlock; Lehana Thabane
Journal:  Can J Surg       Date:  2007-08       Impact factor: 2.089

3.  Comparison of S100B and NSE between cardiac surgery and interventional therapy for children.

Authors:  Yu Liu; Ying Xu; Da-zhen Li; Yuan Shi; Mao Ye
Journal:  Pediatr Cardiol       Date:  2009-05-27       Impact factor: 1.655

4.  Microemboli from cardiopulmonary bypass are associated with a serum marker of brain injury.

Authors:  Robert C Groom; Reed D Quinn; Paul Lennon; Janine Welch; Robert S Kramer; Cathy S Ross; Peter A Beaulieu; Jeremiah R Brown; David J Malenka; Gerald T O'Connor; Donald S Likosky
Journal:  J Extra Corpor Technol       Date:  2010-03

5.  S100B as a biomarker of blood-brain barrier disruption after thoracoabdominal aortic aneurysm repair: a secondary analysis from a prospective cohort study.

Authors:  Derek J Roberts; Richard I Hall; Yan Wang; Lisa C Julien; Jeremy Wood; Kerry B Goralski
Journal:  Can J Anaesth       Date:  2021-09-27       Impact factor: 6.713

Review 6.  Clinical microsystems: a critical framework for crossing the quality chasm.

Authors:  Donald S Likosky
Journal:  J Extra Corpor Technol       Date:  2014-03

Review 7.  S100 and S100β: biomarkers of cerebral damage in cardiac surgery with or without the use of cardiopulmonary bypass.

Authors:  Shi-Min Yuan
Journal:  Rev Bras Cir Cardiovasc       Date:  2014 Oct-Dec
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.