Qualitative and quantitative effects of harmonic echocardiographic imaging on endocardial edge definition and side-lobe artifacts.

D N Rubin1, N Yazbek, M J Garcia, W J Stewart, J D Thomas.   

Abstract

Harmonic imaging is a new ultrasonographic technique that is designed to improve image quality by exploiting the spontaneous generation of higher frequencies as ultrasound propagates through tissue. We studied 51 difficult-to-image patients with blinded side-by-side cineloop evaluation of endocardial border definition by harmonic versus fundamental imaging. In addition, quantitative intensities from cavity versus wall were compared for harmonic versus fundamental imaging. Harmonic imaging improved left ventricular endocardial border delineation over fundamental imaging (superior: harmonic = 71.1%, fundamental = 18.7%; similar: 10.2%; P <.001). Quantitative analysis of 100 wall/cavity combinations demonstrated brighter wall segments and more strikingly darker cavities during harmonic imaging (cavity intensity on a 0 to 255 scale: fundamental = 15.6 +/- 8.6; harmonic = 6.0 +/- 5.3; P <.0001), which led to enhanced contrast between the wall and cavity (1.89 versus 1.19, P <.0001). Harmonic imaging reduces side-lobe artifacts, resulting in a darker cavity and brighter walls, thereby improving image contrast and endocardial delineation.

Entities:  

Keywords:  NASA Discipline Cardiopulmonary; Non-NASA Center

Mesh:

Year:  2000        PMID: 11093103     DOI: 10.1067/mje.2000.108348

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  3 in total

1.  Thrombosis on implanted device for atrial septal defect closure or echocardiographic beam width artifact? A diagnostic enigma!

Authors:  Majid Kyavar; Anita Sadeghpour; Azin Alizadehasl; Negar Salehi
Journal:  Int J Cardiovasc Imaging       Date:  2012-02-28       Impact factor: 2.357

2.  Are normative values for LV geometry and mass based on fundamental imaging valid with use of harmonic imaging?

Authors:  Lisa de Las Fuentes; Karen E Spence; Victor G Dávila-Román; Alan D Waggoner
Journal:  J Am Soc Echocardiogr       Date:  2010-09-21       Impact factor: 5.251

3.  Effect of Transmit Beamforming on Clutter Levels in Transthoracic Echocardiography.

Authors:  Vaibhav Kakkad; Melissa LeFevre; Kingshuk Roy Choudhury; Joseph Kisslo; Gregg E Trahey
Journal:  Ultrason Imaging       Date:  2018-04-21       Impact factor: 1.578

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.