Literature DB >> 11092656

A synergistic approach to optimal stenting: directional coronary atherectomy prior to coronary artery stent implantation--the AtheroLink Registry. AtheroLink Study Group.

H W Höpp1, F M Baer, C Ozbek, K H Kuck, B Scheller.   

Abstract

OBJECTIVES: The AtheroLink registry sought to observe the effect of plaque burden reduction by directional coronary atherectomy (DCA) prior to stenting on acute lesion success rate, on the clinical success rate and on the incidence of in-stent restenosis six months after intervention.
BACKGROUND: Although coronary stenting has reduced restenosis, its effect has been less favorable in complex lesions with a high plaque burden that results from suboptimal stent expansion. Therefore, plaque removal by DCA may improve the results of coronary stenting.
METHODS: A total of 167 patients with >60% stenosis in a native coronary artery of 2.8 to 4.0 mm in diameter were enrolled in 10 study centers on an intention-to-treat basis. All patients underwent DCA aimed at an optimal result (residual diameter stenosis <20%) followed by stenting. Angiographic follow-up was performed in 120 (71.8%) patients at 5.3+/-2.8 months.
RESULTS: Lesion success was achieved in 164/167 (98.2%) patients, and the clinical success rate was 95.2% (159/167 patients). The overall restenosis rate in the 120 patients with angiographic follow-up was 10.8% (13/120). Incidence of restenosis was lower (8.4%) in patients with optimal stent deployment following DCA compared to patients with a persisting caliber reduction >15% (restenosis rate 15.3.%) and restenosis occurred with a significantly higher frequency (p<0.04) in distal lesions (37.5%) compared to proximal stenoses (9.0%).
CONCLUSIONS: This observational multicenter registry points to a potential reduction in restenosis by a synergistic approach of DCA and stenting performed under routinely accessible angiographic guidance. Therefore, multicenter-based randomized clinical trials are clearly warranted to finally clarify the validity of this complex approach versus conventional angioplasty plus stenting.

Entities:  

Mesh:

Year:  2000        PMID: 11092656     DOI: 10.1016/s0735-1097(00)00967-0

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  1 in total

1.  MR-velocity mapping in vascular stents to assess peak systolic velocity. In vitro comparison of various stent designs made of Stainless Steel and Nitinol.

Authors:  Jacqueline van Holten; Patrik Kunz; Paul G H Mulder; Peter M T Pattynama; Hildo J Lamb; Lukas C van Dijk
Journal:  MAGMA       Date:  2002-11       Impact factor: 2.310

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.