Literature DB >> 11085381

Intramedullary fixation of cortical bone osteotomies with absorbable self-reinforced fibrillated poly-96L/4D-lactide (SR-PLA96) rods in rabbits.

A Saikku-Bäckström1, R M Tulamo, J E Räihä, M Kellomäki, T Toivonen, P Törmälä, P Rokkanen.   

Abstract

Osteotomies of the femoral diaphysis were fixed with absorbable self-reinforced fibrillated poly-96L/4D-lactide (SR-PLA96) intramedullary rods (4.5 mm x 50-60 mm) in 43 adult rabbits. Follow-up times varied from 3 weeks to 3 yr. After sacrifice histological, oxytetracycline-fluorescence and microradiographic studies of the bones were performed. Strength characteristics and changes in crystallinity and molecular weight of the rods were also measured. All osteotomies were evaluated radiographically. Thirty-six osteotomies (84%) healed uneventfully. The implant disappeared almost totally within 3 yr and histology showed only a minor foreign body reaction. From 6 weeks on, the bending force needed to break the osteotomy was comparable to the bending force needed to break the control bone. The shear strength of the rods displayed only minor changes for the first 24 weeks. Subsequently, the rods rapidly lost their strength and at 48 weeks there was practically no shear strength left, which is ideal for healing of an osteotomy. The present investigation demonstrated, that absorbable. fibrillated SR-PLA96-rods can be used for the intramedullar fixation of simple cortical bone osteotomies in rabbits. These results have encouraged us to continue our studies with the fixation of experimental cortical bone osteotomies in larger species.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11085381     DOI: 10.1016/s0142-9612(00)00142-3

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  5 in total

1.  Tissue restoration after implantation of polyglycolide, polydioxanone, polylevolactide, and metallic pins in cortical bone: an experimental study in rabbits.

Authors:  Harri K Pihlajamäki; Sari T Salminen; Olli Tynninen; Ole M Böstman; Outi Laitinen
Journal:  Calcif Tissue Int       Date:  2010-05-22       Impact factor: 4.333

2.  Flexor tendon healing within the tendon sheath using bioabsorbable poly-L/D-lactide 96/4 suture. A histological in vivo study with rabbits.

Authors:  Anna Viinikainen; Harry Göransson; Hanna-Stina Taskinen; Matias Röyttä; Minna Kellomäki; Pertti Törmälä; Pentti Rokkanen
Journal:  J Mater Sci Mater Med       Date:  2014-01-30       Impact factor: 3.896

3.  Magnetic resonance appearance of bioabsorbable anchor screws for double row arthroscopic rotator cuff repairs.

Authors:  Aditya C Pawaskar; Aashay Kekatpure; Nam-Su Cho; Yong-Girl Rhee; In-Ho Jeon
Journal:  Indian J Orthop       Date:  2015 Mar-Apr       Impact factor: 1.251

4.  Long-term Follow-up of Extensive Peri-anchor (Poly-L/D-lactic Acid) Cyst Formation after Arthroscopic Rotator Cuff Repair: A Case Report.

Authors:  Jong-Ho Kim; Jong-Ick Kim; Hyo-Jin Lee; Dong-Jin Kim; Gwang Young Sung; Dong-Ho Kwak; Yang-Soo Kim
Journal:  Clin Shoulder Elb       Date:  2019-06-01

5.  Effect of the enantiomeric structure of hydrophobic polymers on the encapsulation properties of a second near infrared (NIR-II) fluorescent dye for in vivo deep imaging.

Authors:  Kotoe Ichihashi; Masakazu Umezawa; Yuichi Ueya; Kyohei Okubo; Eiji Takamoto; Takashi Matsuda; Masao Kamimura; Kohei Soga
Journal:  RSC Adv       Date:  2022-01-06       Impact factor: 4.036