Literature DB >> 11080907

Noncontact infrared-mediated thermocycling for effective polymerase chain reaction amplification of DNA in nanoliter volumes.

A F Hühmer1, J P Landers.   

Abstract

We demonstrate that accurate thermocycling of nanoliter volumes is possible using infrared-mediated temperature control. Thermocycling in the presence of Taq polymerase and the appropriate primers for amplification of lambda-DNA in a total volume of 160 nL is shown to result in the successful amplification of a 500-base pair fragment of lambda-DNA. The efficiency of the amplification is sufficiently high so that as few as 10 cycles were required to amplify an adequate mass of DNA for analysis by capillary electrophoresis. This indicates that, as expected, PCR amplification of DNA in nanoliter volumes should not only require less Taq polymerase but require less cycling time to produce a detectable amount of product. This sets the stage for microchip integration of the PCR process in the nanoliter volumes routinely manipulated in electrophoretic microchips.

Mesh:

Substances:

Year:  2000        PMID: 11080907     DOI: 10.1021/ac000423j

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  11 in total

1.  Advancement of analytical modes in a multichannel, microfluidic droplet-based sample chopper employing phase-locked detection.

Authors:  Jean T Negou; Juan Hu; Xiangpeng Li; Christopher J Easley
Journal:  Anal Methods       Date:  2018-06-05       Impact factor: 2.896

2.  Microfabricated valveless devices for thermal bioreactions based on diffusion-limited evaporation.

Authors:  Fang Wang; Ming Yang; Mark A Burns
Journal:  Lab Chip       Date:  2007-10-31       Impact factor: 6.799

3.  Quantitative polymerase chain reaction using infrared heating on a microfluidic chip.

Authors:  Yingjie Yu; Bowei Li; Christopher A Baker; Xinyu Zhang; Michael G Roper
Journal:  Anal Chem       Date:  2012-03-02       Impact factor: 6.986

4.  Microdroplet temperature calibration via thermal dissociation of quenched DNA oligomers.

Authors:  Eric W Hall; Gregory W Faris
Journal:  Biomed Opt Express       Date:  2014-02-13       Impact factor: 3.732

5.  Frequency-encoded laser-induced fluorescence for multiplexed detection in infrared-mediated quantitative PCR.

Authors:  Adrian M Schrell; Michael G Roper
Journal:  Analyst       Date:  2014-06-07       Impact factor: 4.616

6.  Simultaneous detection of multiple HPV DNA via bottom-well microfluidic chip within an infra-red PCR platform.

Authors:  Wenjia Liu; Antony Warden; Jiahui Sun; Guangxia Shen; Xianting Ding
Journal:  Biomicrofluidics       Date:  2018-03-14       Impact factor: 2.800

Review 7.  Advances in microfluidic PCR for point-of-care infectious disease diagnostics.

Authors:  Seungkyung Park; Yi Zhang; Shin Lin; Tza-Huei Wang; Samuel Yang
Journal:  Biotechnol Adv       Date:  2011-06-30       Impact factor: 14.227

8.  Thermally multiplexed polymerase chain reaction.

Authors:  Christopher R Phaneuf; Nikita Pak; D Curtis Saunders; Gregory L Holst; Joav Birjiniuk; Nikita Nagpal; Stephen Culpepper; Emily Popler; Andi L Shane; Robert Jerris; Craig R Forest
Journal:  Biomicrofluidics       Date:  2015-08-10       Impact factor: 2.800

9.  Ultra fast miniaturized real-time PCR: 40 cycles in less than six minutes.

Authors:  Pavel Neuzil; Chunyan Zhang; Juergen Pipper; Sharon Oh; Lang Zhuo
Journal:  Nucleic Acids Res       Date:  2006-06-28       Impact factor: 16.971

10.  How to speed up the polymerase chain reaction.

Authors:  Stephen A Bustin
Journal:  Biomol Detect Quantif       Date:  2017-06-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.