Literature DB >> 11080904

Effective capillary electrophoresis-based heteroduplex analysis through optimization of surface coating and polymer networks.

H Tian1, L C Brody, D Mao, J P Landers.   

Abstract

The efficacy of capillary electrophoresis for detecting DNA mutations via heteroduplex analysis (HDA) is dependent upon both the effective passivition of the capillary surface and the choice of the correct polymer network for sieving. Using HDA with laser-induced fluorescence detection of fluorescently labeled DNA fragments, an effective coating and optimal polymer matrix were sought. Optimized separation conditions were determined through the methodological evaluation of a number of different silanizing reagents, polymeric coatings, and polymer networks for resolving the PCR-amplified DNA fragments associated with five mutations (185delAG, 1294del40, 4446C > G, 5382insC, 5677insA) in the breast cancer susceptibility gene (BRCA1). For capillary coating, allyldimethylchlorosilane, 4-chlorobutyldimethylchlorosilane, (gamma-methacryloxypropyl)trimethoxysilane, chlorodimethyloctylsilane (OCT), and 7-octenyltrimethoxysilane were evaluated as silanizing reagents in combination with poly(vinylprrolidone) (PVP) and polyacrylamide (PA) as the polymeric coat. The HDA results were compared with those obtained using a commercial (FC) coated capillary. Of these, the OCT-PVP combination was found to be most effective. Using this modified capillary, HDA with polymer networks that included hydroxyethylcellulose (HEC), linear polyacrylamide, and PVP showed that a PVP-, PA-, or FC-coated capillary, in combination with HEC as the sieving polymer, could be used effectively to discriminate the mutations in less than 10 min. However, optimal performance was observed with the OCT-PVP-coated capillary and HEC as the polymer network.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11080904     DOI: 10.1021/ac0004916

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  2 in total

1.  Combined SSCP/duplex analysis by capillary electrophoresis for more efficient mutation detection.

Authors:  P Kozlowski; W J Krzyzosiak
Journal:  Nucleic Acids Res       Date:  2001-07-15       Impact factor: 16.971

Review 2.  The use of capillary electrophoresis for DNA polymorphism analysis.

Authors:  Keith R Mitchelson
Journal:  Mol Biotechnol       Date:  2003-05       Impact factor: 2.695

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.