Literature DB >> 11079247

Determination of dioxins/furans and PCBs by quadrupole ion-trap gas chromatography-mass spectrometry.

J B Plomley1, M Lausevic, R E March.   

Abstract

The versatility and sensitivity of the quadrupole ion trap tandem mass spectrometer has been applied to the determination of polychlorodibenzo-p-dioxins (PCDDs) and polychlorodibenzofurans (PCDFs), and of polychlorinated biphenyls (PCBs). A brief introduction to the theory of ion confinement in a quadrupole ion trap permits discussion of ion trajectory stability, mass-selective ion ejection, the frequencies of ion motion, and the role of resonant excitation of ion motion. The tandem mass spectrometric examination of PCDDs and PCDFs eluting and co-eluting from a gas chromatographic column is described. Illustrative examples are given of the analysis of field samples containing PCDDs and PCDFs. A comparison is presented of the performance of each of a quadrupole ion trap tandem mass spectrometer, a triple stage quadrupole mass spectrometer, and a sector instrument of relatively high mass resolution for the determination of PCDDs and PCDFs. This comparison is made with respect to instrument tuning, calibration plots, detection limits, ion signals at low concentration, relative response factors, ionization cross-sections, and the examination of field samples. The application of quadrupole ion trap tandem mass spectrometry to the examination of PCBs is focused upon those PCB congeners that have the greatest toxicity. 39 congeners of the total of 209 PCB congeners have been identified as having the greatest toxicities. Chemical ionization has been used for the determination of co-eluting congeners #77 and #110 where the toxicity of the former is much greater than that of the latter. An analytical protocol, based on the variation of molecular ion fragmentation according to the degree (or absence) of chlorine ortho-substitution, has been proposed for distinguishing between toxic and nontoxic PCB congeners.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11079247     DOI: 10.1002/1098-2787(2000)19:5<305::AID-MAS4>3.0.CO;2-T

Source DB:  PubMed          Journal:  Mass Spectrom Rev        ISSN: 0277-7037            Impact factor:   10.946


  2 in total

1.  Semi-Empirical Topological Method for Prediction of the Relative Retention Time of Polychlorinated Biphenyl Congeners on 18 Different HR GC Columns.

Authors:  Raouf Ghavami; S Mohammad Sajadi
Journal:  Chromatographia       Date:  2010-08-10       Impact factor: 2.044

2.  Generation by a widely applicable approach of a hybrid dioxygenase showing improved oxidation of polychlorobiphenyls.

Authors:  Beatriz Cámara; Michael Seeger; Myriam González; Christine Standfuss-Gabisch; Silke Kahl; Bernd Hofer
Journal:  Appl Environ Microbiol       Date:  2007-02-23       Impact factor: 4.792

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.