Literature DB >> 11078611

Controlled introduction of the sentinel node biopsy in breast cancer in a multi-centre setting: the role of a coordinator for quality control.

A Y de Kanter1, A N van Geel, M A Paul, C H van Eijck, S C Henzen-Logmans, R H Kruyt, E P Krenning, A M Eggermont, T Wiggers.   

Abstract

AIMS: It is proposed that sentinel node biopsy should replace axillary lymph-node dissection. We analysed the role of a coordinator in the introduction of the sentinel node biopsy in breast cancer in a multi-centre setting to assure standardization and quality control.
METHODS: We included 232 operable breast cancer patients. Part of the procedure was an ultrasound examination of the axilla with fine needle aspiration cytology. The sentinel node was identified with 99m-Technetium and Patent Blue.
RESULTS: The results of the procedure, sensitivity and false negativity, were the same for the three participating hospitals. We think this is mostly due to the coordinator who supplied information about the technique, pitfalls and results to all teams.
CONCLUSIONS: Our experience regarding the organization aspects of introducing the sentinel node procedure in a multi-centre setting now serves as a model in organizing its application in a much wider number of hospitals. Copyright 2000 Harcourt Publishers Ltd.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11078611     DOI: 10.1053/ejso.2000.0976

Source DB:  PubMed          Journal:  Eur J Surg Oncol        ISSN: 0748-7983            Impact factor:   4.424


  4 in total

1.  Value of sentinel node biopsy in the management of breast cancer.

Authors:  R Manecksha; A D Hill; B Dijkstra; L Kelly; C D Collins; E McDermott; N J O'Higgins
Journal:  Ir J Med Sci       Date:  2001 Oct-Dec       Impact factor: 1.568

2.  The false-negative rate of sentinel node biopsy in patients with breast cancer: a meta-analysis.

Authors:  Sarah Pesek; Taka Ashikaga; Lars Erik Krag; David Krag
Journal:  World J Surg       Date:  2012-09       Impact factor: 3.352

3.  False-negative sentinel node biopsy.

Authors:  Omgo E Nieweg
Journal:  Ann Surg Oncol       Date:  2009-06-12       Impact factor: 5.344

4.  Ultrasonographically-guided fine-needle aspiration of axillary lymph nodes: role in breast cancer management.

Authors:  A Sapino; P Cassoni; E Zanon; F Fraire; S Croce; C Coluccia; M Donadio; G Bussolati
Journal:  Br J Cancer       Date:  2003-03-10       Impact factor: 7.640

  4 in total