Literature DB >> 11078276

Flow dynamics of stenotic aortic valves assessed by signal processing of Doppler spectrograms.

J Bermejo1, J C Antoranz, M A García-Fernández, M M Moreno, J L Delcán.   

Abstract

Clinical assessment of aortic stenosis (AS) is sometimes challenging, because all hemodynamic indexes of severity are modified by flow rate. However, the mechanisms underlying flow dependence remain controversial. Analysis of instantaneous flow dynamics has provided crucial information in a number of cardiovascular disorders and may add new insight into this phenomenon. This study was designed to analyze in vivo the effects of flow interventions on instantaneous valvular dynamics of stenotic valves. For this purpose, a custom algorithm for signal processing of Doppler spectrograms was developed and validated against a control population. Digital Doppler recordings at the aortic valve and left ventricular outflow tract were obtained in 15 patients with AS, at baseline and during low-dose dobutamine infusion; 10 normal subjects were studied as controls. Spectrograms were processed by signal averaging, time alignment, modal-velocity enhancement, envelope tracing, and numerical interpolation. Instantaneous relative aortic valve area (rAVA) was obtained by the continuity equation and plotted against normalized ejection time. Curves were classified as either type A (rapid, early-systolic opening) or type B (slow, end-systolic opening). Curves from controls closely matched prior knowledge of normal valve dynamics, but curves from patients were clearly different: all controls except 2 (80%) had type A, whereas all patients except 3 (80%) had a type B pattern (p = 0.03). Dobutamine infusion in patients increased and slightly anticipated peak rAVA by accelerating valve opening. Despite similar values of area and pressure difference, type B dynamics were associated with lower blood pressure (p = 0.01) and worse long-term outcome (>3 years) than type A flow dynamics (p = 0.02). Signal processing of Doppler spectrograms allows a comprehensive assessment of aortic flow dynamics. Differences in timing of valve aperture and in maximal leaflet excursion account for flow-mediated changes in valve area, suggesting complementary effects of inertia and elasticity on the kinetics of stenotic aortic valves. Flow-dynamic analysis provides novel clinical information regarding physiology of AS unavailable to conventional indexes.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11078276     DOI: 10.1016/s0002-9149(99)00820-6

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  2 in total

Review 1.  Low-gradient aortic valve stenosis: value and limitations of dobutamine stress testing.

Authors:  J Bermejo; R Yotti
Journal:  Heart       Date:  2006-04-18       Impact factor: 5.994

2.  Relationship Between the Ratio of Acceleration Time/Ejection Time and Mortality in Patients With High-Gradient Severe Aortic Stenosis.

Authors:  Alexandre Altes; Nicolas Thellier; Yohann Bohbot; Anne Ringle Griguer; Stéphane Verdun; Franck Levy; Anne Laure Castel; François Delelis; Amandine Mailliet; Christophe Tribouilloy; Sylvestre Maréchaux
Journal:  J Am Heart Assoc       Date:  2021-11-30       Impact factor: 5.501

  2 in total